Addressable Fire Alarm System Smoke Alarm System

Product Details
Customization: Available
Type: Fire Alarm Host
Function: Addressable
Still deciding? Get samples of US$ 450/Set
Request Sample
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
7
Year of Establishment
2012-07-20
  • Addressable Fire Alarm System Smoke Alarm System
  • Addressable Fire Alarm System Smoke Alarm System
  • Addressable Fire Alarm System Smoke Alarm System
Find Similar Products

Basic Info.

Model NO.
FW6000
Alarm Volume (within 1m)
≥80dB
Networking Mode
485/232
Receive Frequency
Wire
Wiring Mode
Bus System
Weight
8kg
Standby Battery
2*12V/12ah
Tempreature
Zero Degree to 40 Degree
AC Power
220V
Line
2 Wire
Transport Package
Carton
Specification
330*120*400MM
Trademark
ALARM
Origin
China
Production Capacity
50000/Month

Product Description

FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed by our company for applications in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices.

Note: COM port needs grounding
1,(Monitoring Start Output)HJ: Active NO terminal to Fire alarm routing device (use jumper to switch  
between passive and active), which will close to connect +24V output after started (each points with a
max output current of 100mA)
2,(Monitoring Start Output)SG: Active NO terminal to Sounder Strobe (Both active and passive modes,  
use jumper to switch between passive and active), which will close to connect +24V output after
started (with max output current of 100mA for each direct-start point)
3,BUS: Non-polarity two-wire bus terminal
4,Linkage power supply output: 24VDC(Max output current 1A)
5,Main board power supply input: 220VAC
6,Grounding Terminal: Grounding

2.4 Technical Specifications
2.4.1 Power Supply:
AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC)
Standby Battery: 2 x 12V/12AH
2.4.2 Operating Environment:
Temperature: 0ºC~+40ºC
Relative Humidity: ≤95%, non-condensing
2.4.3 Capacity: One loop with maximum 240 devices
2.4.4 Display: LCD 128×64 lattice graphic
2.4.5 Dimension: (Length ×Width ×Height):330.0mm×130.0mm×400.0mm
2.4.6 Wiring requirement
1,Recommend to use RVS2×1.0MM2 or RVS2×1.5MM twisted wire for CAN communication wire and bus   
wire, while use RVSP2×1.0MM2 at the high interference environment.
2,Not allowed to lay CAN communication wire and telephone line together with bus wire inside the same        