Spanish Likes Mounting DC9V/AC110-220V Fire Alarm Smoke Detector
Contact Supplier
Product Highlights
- Silence Feature: Temporarily desensitizes circuitry to silence non-emergency alarms like cooking smoke.
- Battery Backup: DC9V battery ensures operation during AC power failure with low battery warning.
- Flashing LED Indicator: Red light flashes every 30-40 seconds to confirm power status and detect faults.
- Photoelectric Sensor: Advanced photoelectric technology detects smoke particles for early fire warning.
- 85dB Alarm Sound: Loud pulsating alarm ensures audible warning even in noisy environments.
- Easy Installation: Ceiling or wall mounting with included bracket and clear step-by-step instructions.
- Weekly Testing: Simple test button allows users to verify circuitry, horn, and power functionality.
- Low Battery Warning: Audible chirp and LED flash alert users 7 days before battery depletion.
Product Attributes
- Customization
- Available
- Type
- Smoke Detectors
- Anti-theft Alarm System Approach
- Active
- Model NO.
- S008
- Anti-Theft Alarm System Type
- Smoke Alarms
- Anti-Theft Alarm System-Wide
- Point Control Alarm Detectors
- Anti-Theft Alarm System Distance
- Common Detectors
- Types of Smoke Detectors
- Photoelectric Smoke Style
- Infrared Sensor Probe Type
- Inclination Sensor
- Infrared Sensor Installation
- Ceiling
- Combustible Gas Detector Model
- NA-300
- Weight
- 185g
- Color
- White
- Input Type
- Sound Light
- Power
- DC9V Battery Backup
- Lound
- 80dB
- Transport Package
- Carton
- Specification
- 148*143*40mm
- Trademark
- alarm
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 500000/Month
Product Images of Spanish Likes Mounting DC9V/AC110-220V Fire Alarm Smoke Detector
Find Similar Products
Product Description
A.C. Powered Photoelectric Smoke Alarm
with Battery Back-Up and Silence Feature
Input: 110V-240V AC ~ 50-60Hz, 0.04A
USER'S MANUAL
SMOKE ALARMS
IMPORTANT!
CONTENTS OF THIS MANUAL
1 -- RECOMMENDED INSTALLATION LOCATIONS
2 -- LOCATIONS TO AVOID FOR SMOKE ALARMS
3 -- INSTALLATION INSTRUCTIONS
4 -- OPERATION AND TESTING
5 -- NUISANCE ALARMS
6 -- MAINTENANCE
7 -- LIMITATIONS OF SMOKE ALARMS
8 -- SERVICE
1. RECOMMENDED LOCATIONS FOR ALARMS
• Locate the first alarm in the immediate area of the bedrooms but
not in the bedrooms. Try to protect the exit path as the bedrooms
are usually farthest from the exit. If more than one sleeping area
exists, locate additional alarms adjacent to each sleeping area.
• Locate additional alarms in the bedrooms if required.
• Locate additional alarms to protect any stairway as stairways act
like chimneys for smoke and heat.
• Locate at least one alarm on every floor level.
• Locate an alarm in every room where electrical appliances are
operated (i.e. portable heaters or humidifiers).
• Locate an alarm in every room where someone sleeps with the
door closed. The closed door may prevent the alarm from waking
the sleeper.
• Smoke, heat, and combustion products rise to the ceiling and
spread horizontally. Mounting the smoke alarm on the ceiling in the
center of the room places it closest to all points in the room. Ceiling
mounting is preferred in ordinary residential construction.
• When mounting an alarm on the ceiling, locate it at a minimum of
4" (10 cm) from the side wall (see Figure 1).
• When mounting the alarm on the wall, it is best to use an inside
wall with the top edge of the alarm at a minimum of 4" (10 cm) and a
maximum of 12" (30.5 cm) below the ceiling, (see Figure 1).
• Put smoke alarms at both ends of a bedroom hallway or large
room if the hallway or room is more than 30 feet (9.1 m) long.
• Install Smoke Alarms on sloped, peaked or cathedral ceilings at or
within 3ft (0.9m) of the highest point (measured horizontally). (see
Figure 2).
2. LOCATIONS TO AVOID FOR ALARMS
Alarms must not be located within 3 feet of the following:
• Supply and return registers used for forced air
heating and air conditioning.
• Ceiling fans and other high air flow areas.
• Bathrooms which contain a tub or shower.
In general, alarms should not be located:
• In the garage. Products of combustion are present
when you start your automobile.
• In an area where the temperature may fall below
40ºF or rise above 100ºF.
• In dusty areas. Dust particles may cause nuisance
alarms or failure to alarm.
• In a kitchen or cooking area where steam and
smoke from burning food or toast can cause nuisance
alarms.
• Near fluorescent lights. Electronic "noise" may cause
nuisance alarms.
FIGURE 1
![]() |
FIGURE 2
![]() |
3. INSTALLATION INSTRUCTIONS
1. Hold base firmly and twist the mounting bracket
counterclockwise to separate it from the base.
2. Hold the mounting bracket against the ceiling (or wall)
so the vertical mounting slot is aligned in the 12 o'clock
position and trace around the inside of the mounting
slots (vertical and horizontal mounting).
3. Put the unit where it won't get covered with dust when you
drill the mounting holes.
4. Using a 3/16" (5 mm) drill bit, drill a hole through the center
of the oval outlines you traced.
5. Insert the plastic screw anchors (in the plastic bag with
screws) into the holes. Tap the screw anchors gently with a
hammer, if necessary, until they are flush with the ceiling or
wall. (see Figure 3).
6. Attach the mounting bracket to the ceiling or wall.
FIGURE 3 FIGURE 4
![]() |
7. Wiring the A.C. QUICK CONNECT harness (see Figure 4):
WIRES ON HARNESS CONNECTED TO
Brown Hot Side of A.C. Line
Blue Neutral Side of A.C. Line
8. Attach the mounting bracket to the ceiling or wall.
9 Install the DC9V battery. Open the battery drawer. Match
the terminals on the end of the battery with the terminals on
the unit. Match "+" to "+" and "-" to "-." Push the battery in until
it snaps in securely and cannot be shaken loose. If the battery
is not snapped in completely, the unit cannot receive battery
power.
10. Attach the Smoke Alarm to the mounting bracket. Line up
the guides on the alarm's base with the guides on the
mounting bracket. When guides are lined up, turn the base
clockwise (right) until it snaps into place.
11. Test the Smoke Alarm. See "Weekly Testing."
4. OPERATION AND TESTING
SILENCE FEATURE (HUSH CONTROL): The Silence
Feature has the capability of temporarily desensitizing the
smoke sensing circuitry in order to quiet your alarm while you
take care of a non-emergency event. This feature is to be
used only when a known alarm condition, such as smoke
from cooking, activates the alarm. When the unit alarm,
activate Silence Feature by pushing the button on the smoke
alarm cover, the alarm "chirp" twice, LED blink twice. If the
smoke is not too dense, the alarm will silence immediately.
The LED will blink twice every 10 seconds for
approximately 7 minutes to indicate that the alarm is in a
temporarily desensitized condition. The smoke alarm will
automatically reset after approximately 7 minutes, and will
sound again if particles of combustion are still present. The
Silence Feature can be used repeatedly until the air has been
cleared of the condition causing the alarm. Pushing the test
button on the alarm will end the Silence Feature period, the
alarm "chirp" once, LED blink once.
OPERATION: The smoke alarm is operating once the AC
power on or a fresh battery is installed and testing is complete.
When products of combustion are sensed, the unit sounds a
loud 85db pulsating alarm until the air is cleared.
FLASHING LED LIGHT: This smoke alarm is equipped with a
flashing red indicator light. The light will flash every 30 - 40
seconds to indicate that the smoke alarm is receiving power
SMOKE SENSING CHAMBER OPERATION: This alarm will
"chirp" if any of the components in the smoke sensing
chamber fail. This chirp will occur between the flashes of the
red LED indicator light. (If the chirp occurs at the same time
as the red LED flash, see Section 6 for low battery
information.)
WEEKLY TESTING: Test by pushing the test button on the
cover when unit in normal status. This will sound the alarm if
the electronic circuitry, horn, and AC power and battery are
working. If no alarm sounds, the unit has defective batteries
or other failure. You can also test the alarm by blowing smoke
into it. TEST THE ALARM WEEKLY TO ENSURE PROPER
OPERATION. Erratic or low sound coming from your alarm
may indicate a defective alarm, and it should be returned for
service.
5. NUISANCE ALARMS
Smoke alarms are designed to minimize nuisance alarms.
Cigarette smoke will not normally set off the alarm, unless the
smoke is blown directly into the alarm. If a smoke detector is
located in a bathroom or kitchen then nuisance alarms will
occur. Follow the "Locations to Avoid for Alarms" Section.
6. MAINTENANCE
BATTERY REPLACEMENT - To replace the battery, remove
the alarm from the mounting bracket by rotating the alarm
counterclockwise. The Smoke Alarm is powered by a DC 9V
battery. A fresh battery should last for one year under normal
operating conditions. When AC Power off, this alarm has a
low battery monitor circuit which will cause the alarm to
"chirp" approximately every 30 - 40 seconds for a minimum of
seven (7) days, accompanied by the red LED flash, when the
battery gets low. Replace the battery when this condition
occurs.
CLEANING YOUR ALARM - To clean your alarm, remove it
from the mounting bracket as outlined in the beginning of this
section. You can clean your alarm by using compressed air or
your vacuum cleaner hose to blow or suck air through the
openings around the perimeter of the alarm. The outside of
the alarm can be wiped with a damp cloth. After cleaning,
reinstall your alarm. Test your alarm by using the test button.
7. LIMITATIONS OF SMOKE ALARMS
Smoke alarms are devices that can provide early warning of
possible fires at a reasonable cost; however, alarms have
sensing limitations.
• A battery powered alarm must have a battery of the
specified type, in good condition and installed properly.
• Smoke alarms must be tested regularly to make sure the
batteries and the alarm circuits are operating correctly.
• Smoke alarms cannot provide an alarm if smoke does not
reach the alarm. Therefore, smoke alarms may not sense
fires starting in chimneys, walls, on roofs, on the other side of
a closed door or on a different floor.
• If the alarm is located outside the bedroom or on a different
floor, it may not wake up a sound sleeper.
• The use of alcohol or drugs may also impair one's ability to
hear the smoke alarm. For maximum protection, a smoke
alarm should be installed in each sleeping area on every level
of a home.
• Although smoke alarms can help save lives by providing an
early warning of a fire, they are not a substitute for an
insurance policy. Home owners and renters should have
adequate insurance to protect their lives and property.
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- How long does a fresh battery last?
- A fresh DC9V battery should last for one year under normal operating conditions.
- Can the alarm be silenced if triggered by cooking?
- Yes, the Silence Feature allows you to temporarily desensitize the alarm for non-emergency events.
- Where should the smoke alarm be installed?
- Install on the ceiling at least 4 inches from walls, or on walls 4 to 12 inches below the ceiling, avoiding kitchens and bathrooms.
- What happens when the battery is low?
- The alarm will chirp every 30-40 seconds and the red LED will flash for a minimum of seven days.
- How often should the alarm be tested?
- You should test the alarm weekly by pushing the test button to ensure proper operation.
- What is the power input requirement?
- The alarm operates on 110V-240V AC at 50-60Hz and includes a DC9V battery backup.
- How do I clean the smoke alarm?
- Use compressed air or a vacuum hose to clean the openings, and wipe the outside with a damp cloth.
- What is the alarm sound level?
- The alarm produces a loud 85dB pulsating sound when combustion products are sensed.
Send your message to this supplier
People who viewed this also viewed
-
US$150.00-180.00 / Set
-
US$350.00-450.00 / Piece
-
US$380.00-450.00 / Piece
-
US$90.00-150.00 / Piece
-
US$90.00-150.00 / Piece
-
US$150.00-180.00 / Set
-
US$380.00-450.00 / Piece
-
US$380.00-450.00 / Piece
-
US$380.00-450.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Alone Smoke Detetors
- Others Alone Smoke Detetors
- Spanish Likes Mounting DC9V/AC110-220V Fire Alarm Smoke Detector
Related Categories
Hot Searches
- Fire Alarm Factories
- Door Alarm Factories
- Alarm Security Factories
- Fire Alarm System Factories
- Alarm Sensor Detector
- Smoke Alarm Sensor
- Smoke Detector Alarm System
- Alarm Detector Smoke Sensor
- Smoke Co Detector Alarm
- Fire Alarm Detector Bulkbuy