Automatic Resetting of Zones Gas Extinguishing Panel with Emergency Hold Device
Contact Supplier
Product Highlights
- EN54 & EN12094 Compliance: Designed in accordance with European standards EN54-2, EN54-4, and EN12094-1 for safety and reliability.
- Four Detection Zones: Features four Style B initiating device circuits capable of contributing to extinguishant release decisions.
- Automatic Zone Reset: Includes test conditions allowing automatic resetting of zones in alarm for efficient testing purposes.
- Emergency Hold Device: Enables extension of the extinguishant delay time to allow for verification before evacuation.
- 75-Second Delay Option: Supports a delay of extinguishing signal up to 75 seconds for alarm verification.
- Dual Relay Contacts: Provides voltage-free relay contacts for fire and local fire signaling with 2A/30VDC rating.
- Battery Backup System: Integral mains-powered battery charger with two 12V sealed lead-acid batteries for continuous operation.
- Manual Override Mode: Offers manual-only mode to disable automatic release of extinguishant via detection devices.
Product Attributes
- Customization
- Available
- Type
- Fire Alarm Host
- Function
- Networked
- Model NO.
- CM1004
- Usage
- Auto, Fire, Smoke
- Certification
- CE
- Alarm Volume (within 1m)
- ≥100dB
- Networking Mode
- Dial-up
- Receive Frequency
- Wire
- Wiring Mode
- Sub-Line System
- Main Supply
- 90-270VAC, 50/60 Hz
- Number of System Zones
- 4 Zone
- Panel Weight
- 5kg
- Extinguishant Release Output
- 21V-28VDC. Maximum Load 2 AMP
- Alarm Zone End of Line (Ohms)
- 10K
- Power Supply Rating
- 3 AMPS Total Including Battery Charge 28V+/-2V
- Battery Type
- Two 12 Volt Sealed Lead Acid in Series
- Battery Charge Voltage
- 27.6VDC Nominal
- Battery Charge Current
- 0.7A Maximum
- Maximum Current Draw From Battery
- 3AMPS
- Fault Relay Contact Rating
- 2A /30VDC Maximum for Each
- Fire Relay Contact Rating
- 2A /30VDC Maximum for Each
- First Stage Contact Rating
- 2A /30VDC Maximum for Each
- Second Stage Contact Rating
- 2A /30VDC Maximum for Each
- Extract Contact Rating
- 2A /30VDC Maximum for Each
- Transport Package
- Carton
- Specification
- 383*295*87MM
- Trademark
- Extinguish
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 500000/Month
Product Images of Automatic Resetting of Zones Gas Extinguishing Panel with Emergency Hold Device
Find Similar Products
Product Description
|
1. Key Specifications/Special Features |
||
|
2. Outview
The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing system and has four detection zones, any or all of which are capable of contributing to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.
In addition to the requirements of EN54-2 the control panel has the following facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes. EN54-2 Section 10 option with requirements
Delay of the actioning of fire alarm devices (sounders) so that an alarm may be verified before a premises is evacuated. EN54-2 Section 7.11 option with requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises upon the detection of a fire condition or the operation of a manual call point. EN54-2 Section 7.8 option with requirements
In addition to the requirements of EN54-2, all control panels have voltage free relay contacts for fire and local fire which operate upon a fire condition. These are to be used for local control and signaling.
In addition to the requirements of EN12094-1 the control panel has the following facilities:
Delay of extinguishing signal of up to 75 seconds. EN12094-1 Section 4.17 option with requirements.
Signal representing the flow of extinguishing agent to indicate the released condition. EN12094-1 Section 4.18 option with requirements.
Monitoring of the status of components by way of a low pressure switch input. EN12094-1 Section 4.19 option with requirements.
Emergency hold device to enable the extinguishant delay time to be extended. EN12094-1 Section 4.20 option with requirements.
Control of flooding time to deactivate the releasing output after a set period of time. EN12094-1 Section 4.21 option with requirements.
Manual only mode to disable the release of extinguishant via automatic detection devices. EN12094-1 Section 4.23 option with requirements.
Triggering of equipment outside the system by way of first and second stage contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements
Activation of alarm devices with different signals to indicate pre-discharge and released warnings using different sounds. EN12094-1 Section 4.30 option with requirements.
3. Safety
Suppliers of articles for use at work are required under section 6 of the Health and Safety at Work act 1974 to ensure as reasonably as is practical that the article will be safe and without risk to health when properly used.
An article is not regarded as properly used if it is used 'without regard to any relevant information or advice' relating to its use made available by the supplier.
This product should be installed, commissioned and maintained by trained service personnel in accordance with the following:
(i) IEE regulations for electrical equipment in buildings
(ii) Codes of practice
(iii) Statutory requirements
(iv) Any instructions specifically advised by the manufacturer
According to the provisions of the Act you are therefore requested to take such steps as are necessary to ensure that you make any appropriate information about this product available to anyone concerned with its use.
This equipment is designed to operate from 230V/50Hz mains supplies and is of class 1 construction. As such it must be connected to a protective earthing conductor in the fixed wiring of the installation and a readily accessible double pole disconnect device meeting the requirements of EN60950/IEC950 which disconnects live and neutral simultaneously shall be incorporated in the fixed wiring.
Switch disconnect devices such as MK Sentry 63A or similar are suitable for this.
Failure to ensure that all conductive accessible parts of this equipment are adequately bonded to the protective earth will render the equipment unsafe.
This control panel is environmental class A and is designed for indoor use only at temperatures between -50ºC(+/- 3) and +400ºC (+/- 2) and with a maximum relative humidity of 95%.
The IP rating for the enclosure is IP30.
Operation outside of these limits may render the equipment unsafe.
![]() |
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- What European standards does this panel comply with?
- It is designed according to EN54-2, EN54-4 for fire detection systems and EN12094-1 for gas extinguishing systems.
- How many detection zones does the panel support?
- The panel supports four Style B initiating device circuits, all capable of contributing to the extinguishant release decision.
- Can the zones be automatically reset after an alarm?
- Yes, the panel includes a test condition that allows for the automatic resetting of zones in alarm for testing purposes.
- What is the maximum delay time for the extinguishing signal?
- The panel supports a delay of the extinguishing signal of up to 75 seconds to allow for alarm verification.
- Does the panel include a battery backup?
- Yes, it features an integral battery charger with two 12-volt sealed lead-acid batteries connected in series.
- Is there a manual mode to prevent automatic release?
- Yes, it offers a manual-only mode that disables the release of extinguishant via automatic detection devices.
- What type of relay contacts are provided?
- It includes voltage-free relay contacts for fire and local fire, rated at 2A / 30VDC maximum for each contact.
Send your message to this supplier
People who viewed this also viewed
-
US$25.00-35.00 / Piece
-
US$550.00-680.00 / Set
-
US$155.00-170.00 / Piece
-
US$135.00-170.00 / Piece
-
US$95.00-120.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-50.00 / Piece
-
US$50.00-60.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Extinguishant Control Systen
- Others Extinguishant Control Systen
- Automatic Resetting of Zones Gas Extinguishing Panel with Emergency Hold Device
Related Categories
Hot Searches
- Fire Alarm Factories
- Fire System
- Alarm Control System Factories
- Fire Fighting System
- Fire Alarm System Companies
- Fire Alarm System Installation
- Fire Security Alarm System
- Fire Alarm Control System
- Electric Alarm Fire System
- Extinguishant Control System Bulkbuy