UL Certification Linear Heat Detector Linear Fire Alarm Cable in Tunnel
Contact Supplier
Product Attributes
- Customization
- Available
- Type
- Metal Detector
- Usage
- Metal, Temperature
- Model NO.
- MS1000
- Installation Mode
- Built in
- Certification
- CE, FM
- Material of Core Conductor
- Streel
- Diameter of Core Conductor
- 0.92mm
- Resistance Core Conductor
- 0.64±0.06Ω/M
- Transport Package
- Carton
- Specification
- 1.5m2
- Trademark
- Linear heat detector
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 500000/Momth
Product Images of UL Certification Linear Heat Detector Linear Fire Alarm Cable in Tunnel
Find Similar Products
Product Description
here are multiple types of LHD, Conventional Type, Outdoor Type, High performance of Chemical Resistance Type and Explosion Proof Type, each type has its own feature and applications. Please choose the right type according to the factual situation.
Description of matching electrical equipments
MS1000 is digital type LHD with comparatively simple output signal. And Shenyang P.T.S. sales matching electrical equipments to MS1000.
MS1000-I Linear Detector Interface |
1.Interface for MS1000, MS1000-CR,MS1000-OD and MS1000-EP digital linear heat cable With local fire and fault indication Fire and fault relay output available Low-power design Metal case |
| Technical Specifications Operating Voltage:24VDC Operating Voltage Range: 16VDC-28VDC Operating Current: Standby Current:≤20mA Fire Current:≤30mA Fault Current:≤25mA Operating environment: Temperature:-45ºC-60ºC Relative humidity:95% IP Rating :Ip66 Dimensions:90mm × 85mm × 52mm(L×W×H) |
|
MS1000-P End of Line Unit |
End of Line Unit for MS1000, MS1000-CR,MS1000-OD and MS1000-EP digital linear heat cable The functions are balancing the signal status For Digital linear heat cable monitoring and alarm/fault simulating (Notice: "Fire Test" pushbutton is for testing use only) |
| Technical Specifications Operating Voltage: No Electronics Operating environment: Temperature:-45ºC-60ºC Relative humidity:95% IP Rating :IP66 Dimensions:90mm×85mm×52mm(L×W×H) |
The consumers can choose other electrical equipments to connect with MS1000, making good preparation as followed:
(1)Analysing the protection capability of the equipments(input terminal). For during the operating, the LHD may couple the signal of the protected device(power cable),causing voltage surge or current impact to the input terminal of the connecting equipment.
(2)Analysing the anti-EMI capability of the equipments(input terminal). Because long-length use of LHD during the operation, there may be power frequency or radio frequency from LHD itself interfering the signal.
(3)Analysing what is the maximum length of LHD the equipments can connect.
This analysis should depend on the technical parameters of MS1000, which will be introduced in detail later in this manual.
If any other queries relating, please contact us for more information. Our engineers will provide technical support.
Connecting instruction
- Connecting drawing of MS1000-I ( Drawing 1)
![]() |
- C1 C2:with sensor cable, non-polarized connection
- A B:with DC24V power,non-polarized connection
- COM NC:fault output
- COM NO:fire alarm output (resistance value in fire alarm ≤50Ω)
- Connecting drawing of MS1000-P ( Drawing 2)
![]() |
(Drawing 2)
- C1 C2:with sensor cable, non-polarized connection
- XT2 : connected with 4.7k terminal resistance
The linear heat detector is a type of fire detector with advanced functions, which meet all kinds of fire protection requirements in any inflammable sites. Though the detector has strong protective outer jacket to prevent damage, more attention should be paid during the installation due to the partial and internal damage cannot be found immediately. The damaged cable may cause the alarm of system malfunction or alarm during the future use. As a result, the followings should be paid attention to:
1. Forbid heavy objects overwhelming the heat sensing cable;
2. Forbid bending or turning the heat sensing cable with an acute angle;
3. Prevent corrosion;
4. Forbid using nonstandard accessories on the linear heat cable.
5. "Fire Test" pushbutton on the End of Line Unit is for testing use only, it must be restricted to prevent accidental or mistaken use.
It comes to different fire detecting results due to different methods of installation, so we need take all the following factors into consideration, including the height, the structure, the obstruction, the air flow and so on, to prevent improper installation adversely affecting the normal use of the detector.
The installation spacing of LHD
Characteristic features of LHD makes itself become the best choice of fire alarm system for applications in high risk of flammable areas, major types of industrial and commercial places, especially in some harsh environments where spot-type detectors cannot be installed.
The LHD of Shenyang P.T.S has been widely applied in industrial warehouses, workshops, etc. The detector can be installed at the ceiling level or the side wall depending on the features of the protected device, getting the same detecting result as the spot-type detectors'.
How to determine the installation spacing?
There are different instructions from UL and FM standards, according to their own test requirements, the detector should match the figures below:
| Model | Approvals/Max. Listed Spacing | |
| FM | UL/cUL | |
| MS1000 68ºC MS1000-CR 68ºC MS1000-OD 68ºC MS1000-EP 68ºC |
7.7m |
15.2m |
| MS1000 88ºC MS1000-CR 88ºC MS1000-OD 88ºC MS1000-EP 88ºC |
7.7m |
15.2m |
| MS1000 105ºC MS1000-CR 105ºC MS1000-OD 105ºC MS1000-EP 105ºC |
4.5m | 15.2m |
| MS1000 138ºC MS1000-CR 138ºC MS1000-OD 138ºC MS1000-EP 138ºC |
4.5m | 15.2m |
| MS1000 180ºC MS1000-CR 180ºC MS1000-OD 180ºC MS1000-EP 180ºC |
N/A Special applications |
N/A Special applications |
We should design and lay the LHD with practice, properly reduce the spacing among the LHD to guarantee the accurate fire alarm. 5m spacing among LHDs is the best distance to get good detecting performance on our experience.
![]() ![]() |
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
Send your message to this supplier
People who viewed this also viewed
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$6.80-8.10 / Piece
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$62.00-75.00 / Piece
-
US$3.80-5.80 / Piece
-
US$2.50-3.60 / Piece
-
US$2.60-3.60 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Linear heat detector
- UL Certification Linear Heat Detector Linear Fire Alarm Cable in Tunnel
Related Categories
Hot Searches
- Fire Alarm Factories
- Fire System
- Fire Fighting System
- Fire Alarm System Factories
- Cable Detector
- Heat Fire Alarm
- Temperature Heat Detector
- Heat Detector Alarm
- Fire Heat Detector
- Fire Alarm System Cable Bulkbuy