2 to 8 Zones Conventional Fire Alarm Control Panel

Product Details
Customization: Available
Type: Fire Alarm Host
Function: Networked
Still deciding? Get samples of US$ 75/Piece
Request Sample
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
7
Year of Establishment
2012-07-20
  • 2 to 8 Zones Conventional Fire Alarm Control Panel
  • 2 to 8 Zones Conventional Fire Alarm Control Panel
  • 2 to 8 Zones Conventional Fire Alarm Control Panel
  • 2 to 8 Zones Conventional Fire Alarm Control Panel
  • 2 to 8 Zones Conventional Fire Alarm Control Panel
  • 2 to 8 Zones Conventional Fire Alarm Control Panel
Find Similar Products

Basic Info.

Model NO.
CP1004
Usage
Fire, Smoke
Certification
CE
Alarm Volume (within 1m)
≥100dB
Networking Mode
Alarm
Receive Frequency
485/232
Wiring Mode
Sub-Line System
Weight [Without Battery ]
520g
Number of Zones
4
Primary AC
90-270VDC
Standby Battery
2*12V
Detector Voltage(VDC)
24VDC
Maximum Number of Detectors Per Zone
30
Transport Package
Carton
Specification
108*143*40mm
Trademark
panel
Origin
China
HS Code
8531100000
Production Capacity
500000/Month

Product Description

EXTERNAL (KEYSWITCH OPERATED) 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders

INTERNAL 

• One Man Detector Test 

• Zone isolate 

• Revert to short circuit = fire (no resistors in call points)

 

EXTERNAL INDICATORS 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders
 

INTERNAL INDICATORS 

• Open circuit zone fault 

• Short circuit zone fault 

• Zone isolate 

• Engineer test selected

 

2 to 8 Zones Conventional Fire Alarm Control Panel
 


OUTPUTS

Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)

Ancillary connections for expansion modules will allow the following:

1.Repeater panels

2.Multiple sounder outputs

3.Connection to landlord panel
 

Input Voltage AC 100-240V, 50/60Hz
Internal Power Supply DC 30V 3A
Total Output Current ≤200mA @ 220V
Chipset 32-bit Micro processor
Zone 1-8 Zone(s)
Max Number of Smoke Detector per Zone 20-25 pcs
 
Capacity High EMI Immunity
Backup Battery DC 12V/2.2AH * 2 (not include)
Dimension 325x265x100mm
Operating Temperature 0ºC ~ +50ºC
Weight(Without battery) 2700g
Material  Iron

2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
2 to 8 Zones Conventional Fire Alarm Control Panel
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.