  • Master-Slave Network Architecture: One master panel connects up to 31 slave panels for centralized monitoring.
  • Dual Zone Detection Capacity: Each panel supports 2 zones with up to 25 conventional detectors per zone.
  • Comprehensive Fault Monitoring: Features end-of-line, short circuit, and open circuit detection capabilities.
  • Flexible Power Supply Options: Supports AC 90-270V input with two 4AH batteries housed in the cabinet.
  • Advanced Relay Control System: Includes Fire 1, Fire 2 (30s delay), Sound, and Fault relay outputs.
  • Compact and Lightweight Design: Mini size of 108x143x40mm with a lightweight 2.2kg body.
  • Long-Range Communication Port: RS485 port supports repeater connections up to 1.2 kilometers.
  • Clear Status Indication: Master panel features 4 digital LED displays for slave number and status.

Product Images of 2 Zone Conventional Fire Alarm Control Panel Facp Detector System

2 Zone Conventional Fire Alarm Control Panel Facp Detector System
2 Zone Conventional Fire Alarm Control Panel Facp Detector System pictures & photos
2 Zone Conventional Fire Alarm Control Panel Facp Detector System
2 Zone Conventional Fire Alarm Control Panel Facp Detector System pictures & photos
2 Zone Conventional Fire Alarm Control Panel Facp Detector System
2 Zone Conventional Fire Alarm Control Panel Facp Detector System pictures & photos
2 Zone Conventional Fire Alarm Control Panel Facp Detector System
2 Zone Conventional Fire Alarm Control Panel Facp Detector System pictures & photos
2 Zone Conventional Fire Alarm Control Panel Facp Detector System
2 Zone Conventional Fire Alarm Control Panel Facp Detector System pictures & photos
2 Zone Conventional Fire Alarm Control Panel Facp Detector System
2 Zone Conventional Fire Alarm Control Panel Facp Detector System pictures & photos
2 Zone Conventional Fire Alarm Control Panel Facp Detector System
  • 2 Zone Conventional Fire Alarm Control Panel Facp Detector System
  • 2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System
  • 2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System
  • 2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System
  • 2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System
  • 2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System
  • 2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System

Find Similar Products

Product Description

 2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.

Key Specifications/Special Features

  • Four Style B (Class B) Initiating Device Circuits (IDCs).
  • One Master Panel also has two zones, each zone can connect max.25 conventional detectors.
  • One slave Panel has two zones, each zone can connect max.25 conventional detectors.
  • The Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.
  • Mini size as 108X143X40mm
  • Master panel has 4 digital LED display to show slave number and status.
  • 2 Detection Zones Panel, 25 Detectors per Zone
  • Fire 1 relay would be activated when one zone alarms.
  • Fire 2 relay would be activated after 30 seconds delay when two zones alarm.
  • 1 Sound relay output for sound alarm
  • 1 Fault relay output for fault condition
  • Zones Fire and Fault LEDs indication
  • Fire1, Fire2, Sound relay outputs can be activated manually
  • RS485 Port for repeater up to 1.2Km
  • Up to 31 Slave panels can be connected to one Master panel
  • Powered by outside DC22-26V power supply
  • End Of Line Status Detection, Short circuit /open circuit detection
  • Two modules power supply could be selected.
  • The power supply input is AC90-270V
  • Two 4AH batteries can be housed in the power supply cabinet.
  • Relay output contacts rated at: 2.0 amps @ 30 VDC.2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System
    2 Zone Conventional Fire Alarm Control Panel Facp Detector System

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

How many slave panels can one master panel support?
One master panel can connect up to 31 slave panels.
What is the maximum number of detectors per zone?
Each zone can connect a maximum of 25 conventional detectors.
What are the power supply requirements?
The system accepts AC 90-270V input and includes two 4AH batteries.
Does the system support fault detection?
Yes, it features end-of-line, short circuit, and open circuit detection.
What is the communication range for the RS485 port?
The RS485 port supports repeater connections up to 1.2 kilometers.
What are the dimensions of the master panel?
The master panel has a compact size of 108x143x40mm.
Can the relay outputs be activated manually?
Yes, Fire 1, Fire 2, and Sound relay outputs can be activated manually.