High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Advanced Electronic Code: Improves coding flexibility and anti-interference ability for temperature detection.
  • High Sensitivity Thermal Elements: Ensures fast response speed for accurate fire detection in home and communication products.
  • 2-Wire Nonpolarity System: Supports linkage type installation with simplified wiring requirements using RVS cables.
  • LED Status Indication: Provides clear visual feedback for normal, fire, and failure statuses via blinking or lighting patterns.
  • Wide Operating Environment: Functions reliably in temperatures from -10 to 50 degrees Celsius with up to 90% relative humidity.
  • CE Certified Safety: Meets strict European safety standards for fire detection equipment.
  • Compact and Lightweight: Weighs only 120g with a white finish, suitable for ceiling mounting in standard 86H50 boxes.
  • Live Address Coding: Allows unique address assignment (1-242) using handheld encoder P6010 for easy system setup.

Product Images of High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System

High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System pictures & photos
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System pictures & photos
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System pictures & photos
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System pictures & photos
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System pictures & photos
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System pictures & photos
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
  • High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
    High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
  • High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
    High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
  • High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
    High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
  • High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
    High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
  • High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
    High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
  • High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
    High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System

Find Similar Products

Product Description

Instruction manual of H-6002 heat detector  

A. Features

1.Built-in product ID code
2.Using hardware and software filtering to improve the anti-interference ability of the temperature detector
3.2 bus, linkage type,nonpolarity
4.Advanced electronic code technology improves the flexibility of coding
5. Using highly sensitive thermal elements to improve the response speed of temperature sensor.

B. Specifications

1.Working voltage: 15-28V Impulse voltage
2.Working current:
1)Standby current: ≤0.5mA
2)Alarm current: ≤3.0mA
3.Type:2 bus(nonpolarity)
4.Encoding: Electronic code
5.Temperature detector's status indication:
1)Normal monitoring status: LED light will blink periodically
2)Fire status: remain lit
3)Failure status: LED light remain off or blink irregularly
6.Operating environment:Temperature-10ºC~50ºC, Relative humidity≤90%RH no condensation
7.Color: white
8.Weight:120g
9. Executive standard:GB 4716-2005

C. Outline diagram

(Figure 1)


Figure 1:H-6002 Dimensions  

High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System


 

D. Installation

1.Installation method
Figure 2 shows the installation of the temperature detector


   
Figure 2 H-6002 installation diagram
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System

86H50 standard embedded box can be used as pre-embedded box; when installation, locate heat detector on the base and rotate clockwise.

2. Wiring requirements: Wire should be RVS-2 * 1.0 mm2 or 1.5 mm2
3. WARNING: Before installing the heat detector, turn off the power and make sure that all the bases are installed securely.

E. Use and operation
Encoding operation: you can use our company's hand-held encoder p6010 to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242, the address code for the same loop is unique). Press the "write code" button, if encoding is successful, the encoder will display the address number after sending the address code. If failed, the encoder will display "FAL" after sending the address code.
For details on the steps and methods of encoding, refer to the P6010  Handheld Encoder User's Manual".
.

F. Note

1. The plastic part attached with heat detector is dust cover. Please cover the dust cover after the installation or room decoration, painting construction, so that the smoke detectors are contaminated.
2. The alarm function test of smoke detector should be performed every six months.
3. When the controller detects the cleaning forecast, please send the number of smoke detectors back to the company for cleaning, in order to avoid false or false positives, resulting in unnecessary losses.

High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
High Sensitivity Home Automation Security Addressable Heat Detector for Fire Detection System
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the working voltage range?
The device operates on a voltage of 15-28V with an impulse voltage tolerance.
How do I set the address code?
Use the P6010 handheld encoder to write a unique address code between 1 and 242 to the device terminals.
What are the LED status indicators?
Normal status blinks periodically, fire status remains lit, and failure status shows off or irregular blinking.
Can this detector be used in humid environments?
Yes, it works in environments with relative humidity up to 90% without condensation.
What type of wiring is required?
Use RVS-2 * 1.0 mm2 or 1.5 mm2 wire for the 2-wire nonpolarity connection.
How often should the alarm function be tested?
The alarm function test should be performed every six months.
What is the lead time for orders?
Lead time is within 15 workdays during off-peak season and one month during peak season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now