Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • CE, RoHS, CCC Certified: Meets international safety and environmental standards for global markets.
  • Three-Year Limited Warranty: Covers defects in materials and workmanship for three years from manufacture date.
  • NO/NC Relay Adjustable: Relay condition can be switched from normally open to normally closed via jumper.
  • Wide Voltage Range: Operates on DC 9V to 28V for flexible power supply compatibility.
  • Durable Construction: Designed for ceiling mounting with robust plastic housing and thermistor protection.
  • Clear LED Indicators: LED flashes every 6 seconds for normal status and continuous light during alarm.
  • Easy Maintenance: Features removable cover and screen assembly for simple vacuum cleaning.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE

Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE pictures & photos
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE pictures & photos
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE pictures & photos
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE pictures & photos
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE pictures & photos
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE pictures & photos
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
  • Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
  • Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
    Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
  • Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
    Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
  • Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
    Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
  • Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
    Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
  • Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
    Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
  • Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
    Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE

Find Similar Products

Product Description

Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE
 
1. Align detector head alignment mark line with the base's start alignment mark line as shown in Figure 2 2. Push the detector head into the base while turning it clockwise to secure it in place. 3. Do not install the detector head until the area is thoroughly cleaned of construction debris, dusts, etc. 4. After all detectors have been installed, apply power to the control panel. 5. Test the detector(s) as described in the TESTING section of this manual. 6. Notify the proper authorities that the system is in operation. ADJUSTING THE RELAY FOR NO/NC The default condition for the relay is "normally open" (NO). 1. To adjust the normal condition of the relay to "normally closed" (NC), use a flat head screwdriver to open the detector head form the bottom. 2. There is a jumper head next to the relay on the PCB. Remove the jumper head and reinsert it in the NC position. 3. Carefully reinstall the head front cover. REMOVE POWER FROM THE PANEL BEFORE INSTALLING DETECTORS. 4. TESTING Before testing, notify the proper authorities that the smoke/heat detector system is undergoing maintenance and will temporarily be out of service. Disable the zone or system undergoing maintenance to prevent unwanted alarms. Detectors must be tested after installation and as part of periodic maintenance. NOTE: 1. Before testing the detector, check to ensure the LEDs blink. If they do not, the detector has lost power (check the wiring), it is defective (return it for repair), or the detector sensitivity is outside the listed limits. 2. All the alarm signal services, releasing device and extinguisher system should be disengaged during the test period and must be re-engaged immediately at the conclusion of testing. 3. After energizing the detector head for approximately one minute, check to see the indicator LED flashing once every 6 seconds. If the LED fails to flash, it indicates the non-functioning of the detector or faulty wiring. Re-check the wiring or replace the detector if necessary. SMOKE SENSOR TESTING (only for smoke detector and smoke & heat detector) Allow smoke from a cotton wick or a test smoke aerosol to enter the detector-sensing chamber for at least 10 seconds. When sufficient smoke has entered the chamber, the detector will signal an alarm, this being visible by a continuous illumination of the LED. Reset each detector and/or control panel before attempting to test any additional detectors in the same zone. If the alarm fails in this step, it indicates a defective unit, which requires service. HEAT SENSOR TESTING (only for heat detector and smoke & heat detector) A hair dryer of 1000-1500 watts should be used to test the heat sensor. Direct the heat toward the heat sensor, holding the heat source approximately 12 inches from the detector in order to avoid damaging the plastic housing. The detector will reset only after it has had sufficient time to cool. A sensor that fails any of these tests should be cleaned as described under MAINTENANCE, and retested. If the sensor fails after cleaning, it must be replaced. When testing is complete, restore the system to normal operation and notify the proper authorities that the system is back in operation. 5. MAINTENANCE Before removing the detector, notify the proper authorities that the smoke detector system is undergoing maintenance and will be temporarily out of service. Disable the zone or system undergoing maintenance to prevent unwanted alarms. 1. Remove the detector to be cleaned from the system. 2. Remove the detector cover by pressing firmly on each of the four removal tabs that hold the cover in place. 3. Vacuum the screen carefully without removing it. If further cleaning is required continue with Step 4, otherwise skip to Step 7. 4. Remove the chamber cover/screen assembly by pulling it straight out. 5. Use a vacuum cleaner or compressed air to remove dust and debris from the sensing chamber. 6. Reinstall the chamber cover/screen assembly by sliding the edge over the sensing chamber. Turn until it is firmly in place. 7. Replace the cover using the LEDs to align the cover and then gently pushing it until it locks into place. Make sure that the thermistors do not become bent under the cover. 8. Reinstall the detector. 9. Test the detector as described in TESTING. 10. Reconnect disabled circuits. 11. Notify the proper authorities that the system is back on line. THREE YEARS LIMITED WARRANTY STATEMENT We warrant its enclosed detector to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. We make no other express warranty for this detector. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company's obligation of this Warranty shall be limited to the repair or replacement of any part of the detector which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning our technical support number for a Return Authorization number, send defective units postage prepaid to our local representative office. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other warranty expressed or implied whatsoever, even if the loss or damage is caused by the Company's negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CESmoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CESmoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE 
SPECIFICATIONS
Operating Voltage Range: 9 to 28 VDC Volts Non-polarized Standby Current: ≤200µA Maximum Alarm Current (LED on): ≤45mA Alarm Relay Contact Ratings: 2A@ 24V DC Operating Humidity Range: ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing Operating Temperature Range: -10°C to 50°C (14°F to 122°F) Smoke Alarm Sensitivity: 1.06±.26%FT Temperature Alarm Sensitivity: 57°C (135°F) A1R (only for with heat sensor) Height: 55 mm installed in Base Diameter: 103 mm
Smoke Detector No/Nc 12V-24V Switch Output Smoke Alarm with CE

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the warranty period for this smoke detector?
The product comes with a three-year limited warranty covering defects in materials and workmanship from the date of manufacture.
Can the relay output be adjusted?
Yes, the relay can be adjusted from normally open (NO) to normally closed (NC) by removing and reinserting the jumper head on the PCB.
What is the operating voltage range?
The detector operates on a DC voltage range of 9 to 28 volts.
What is the maximum alarm current?
The maximum alarm current with the LED on is 45mA.
How should the detector be cleaned?
Remove the cover and screen assembly, then use a vacuum cleaner or compressed air to remove dust from the sensing chamber.
What certifications does this product have?
The product is certified with CE, RoHS, and CCC standards.