Product Highlights

  • High Device Capacity: Supports up to 240 addressable devices on a single two-wire bus loop.
  • Wall Mount Design: Compact and easy to install on walls for small and medium projects.
  • LCD Graphic Display: Features a 128x64 LCD screen for clear alarm and fault information display.
  • Built-in Printer: Integrated printer allows immediate printing of alarm logs and history.
  • Comprehensive Compatibility: Fully compatible with the entire FW 3 series fire alarm devices and modules.
  • Dual Power Supply: Operates on 220VAC with a 2x12V/12AH standby battery backup.
  • Active/Passive Switching: Jumper selectable terminals for active or passive sounder and routing outputs.
  • Robust STM32 Core: Powered by STM32F103 microcontroller for high reliability and data processing.

Product Images of Fire Protection Fire Detection Alarm Monitor Panel System for School

Fire Protection Fire Detection Alarm Monitor Panel System for School
Fire Protection Fire Detection Alarm Monitor Panel System for School pictures & photos
Fire Protection Fire Detection Alarm Monitor Panel System for School
Fire Protection Fire Detection Alarm Monitor Panel System for School pictures & photos
Fire Protection Fire Detection Alarm Monitor Panel System for School
Fire Protection Fire Detection Alarm Monitor Panel System for School pictures & photos
Fire Protection Fire Detection Alarm Monitor Panel System for School
Fire Protection Fire Detection Alarm Monitor Panel System for School pictures & photos
Fire Protection Fire Detection Alarm Monitor Panel System for School
Fire Protection Fire Detection Alarm Monitor Panel System for School pictures & photos
Fire Protection Fire Detection Alarm Monitor Panel System for School
Fire Protection Fire Detection Alarm Monitor Panel System for School pictures & photos
Fire Protection Fire Detection Alarm Monitor Panel System for School
  • Fire Protection Fire Detection Alarm Monitor Panel System for School
  • Fire Protection Fire Detection Alarm Monitor Panel System for School
    Fire Protection Fire Detection Alarm Monitor Panel System for School
  • Fire Protection Fire Detection Alarm Monitor Panel System for School
    Fire Protection Fire Detection Alarm Monitor Panel System for School
  • Fire Protection Fire Detection Alarm Monitor Panel System for School
    Fire Protection Fire Detection Alarm Monitor Panel System for School
  • Fire Protection Fire Detection Alarm Monitor Panel System for School
    Fire Protection Fire Detection Alarm Monitor Panel System for School
  • Fire Protection Fire Detection Alarm Monitor Panel System for School
    Fire Protection Fire Detection Alarm Monitor Panel System for School
  • Fire Protection Fire Detection Alarm Monitor Panel System for School
    Fire Protection Fire Detection Alarm Monitor Panel System for School

Find Similar Products

Product Description

Installation and Operation Manual

FW6000 Fire Alarm Control Panel



1.1 Powerful Function and High Reliability
This FACP uses two-wire bus system to control up to 240 addressable devices. Wall mount design makes it easy to use and operate. It is compatible with the complete range of the FW 3 series fire alarm devices like intelligent detectors, manual call point, input module, I/O module, etc.


FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed by our company for applications in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices.

Note: COM port needs grounding
1,(Monitoring Start Output)HJ: Active NO terminal to Fire alarm routing device (use jumper to switch  
between passive and active), which will close to connect +24V output after started (each points with a
max output current of 100mA)
2,(Monitoring Start Output)SG: Active NO terminal to Sounder Strobe (Both active and passive modes,  
use jumper to switch between passive and active), which will close to connect +24V output after
started (with max output current of 100mA for each direct-start point)
3,BUS: Non-polarity two-wire bus terminal
4,Linkage power supply output: 24VDC(Max output current 1A)
5,Main board power supply input: 220VAC
6,Grounding Terminal: Grounding

1 Main Board

Main board is fixed on the inside upper part of the door and it includes LCD screen, indicators, operation keys, printer and driver board communication interface etc.
Main board is the control center of the FACP. The hardware circuitry is composed with the SCM STM32F103 as a core and extended with some memory chips, keypad, indicators and LCD, etc. This SCM directly control the output keys through its asynchronous serial COM interface and loop diver board to realize the data communication (sending out the action order and receive feedback data ), data analysis, status adjustment as well as sending and record of all sorts of alarm info (audible/visible info, LCD display, print-out record and history log). It can also receive the keyboard operational info to enter all kinds of relevant menu operation interfaces so that to check or set up the FACP control features and status info, and it can receive power supply's working status info as well.
2 Printer Board
It consists of SCM STM32F101, memory chip and indicators, which compose the hardware circuitry to receive the printable data and commands from the main board, and to process and print out the data received.
3 Loop driver board
Loop driver board is used to connect the power supply with main board by SCM STM32F101 and the peripheral circuitry.
The loop part of the driver board consists of SCM STM32F101, memory chip, bus power driver circuit (MOSFET 9024 and 024), feedback code receiving & verification circuit (LM339) etc. Its software is to receive the commands from the main board, then, after the format conversion, forward the commands to the loop connecting to the field devices; it also receive the feedback info from the loop devices and send the info back to the main board.
4 Power Supply
This power supply circuit board transforms 220VAC power to 24VDC for power supply to main board Fire Protection Fire Detection Alarm Monitor Panel System for School
2.4 Technical Specifications
2.4.1 Power Supply:
AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC)
Standby Battery: 2 x 12V/12AH
2.4.2 Operating Environment:
Temperature: 0ºC~+40ºC
Relative Humidity: ≤95%, non-condensing
2.4.3 Capacity: One loop with maximum 240 devices
2.4.4 Display: LCD 128×64 lattice graphic
2.4.5 Dimension: (Length ×Width ×Height):330.0mm×130.0mm×400.0mm
2.4.6 Wiring requirement
1,Recommend to use RVS2×1.0MM2 or RVS2×1.5MM twisted wire for CAN communication wire and bus   
wire, while use RVSP2×1.0mm2 at the high interference environment.
2,Not allowed to lay CAN communication wire and telephone line together with bus wire inside the same        
   multi-core cable.
Fire Protection Fire Detection Alarm Monitor Panel System for School
 



 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the maximum number of devices the panel can support?
The FW6000 panel supports a maximum of 240 addressable devices on a single loop.
How is the panel powered and what is the backup battery specification?
It operates on 220VAC nominal voltage and includes a standby battery of 2x12V/12AH.
Can the panel print out alarm information?
Yes, it is equipped with a built-in printer to print out alarms, faults, and history logs.
Is the panel compatible with other devices in the FW 3 series?
Yes, it is compatible with the complete range of FW 3 series devices including detectors and modules.
What are the dimensions of the control panel?
The dimensions are 330.0mm (Length) x 130.0mm (Width) x 400.0mm (Height).
What type of wiring is recommended for the bus connection?
RVS2x1.0MM2 or RVS2x1.5MM twisted wire is recommended; RVSP2x1.0mm2 for high interference environments.
What is the lead time for orders during peak and off-peak seasons?
Peak season lead time is one month, while off-peak season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now