Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Photoelectric Detection: Uses state-of-the-art optical sensing chamber for reliable smoke detection.
  • Wide Operating Voltage: Operates within 9 to 28VDC range with non-polarized connection.
  • Tamper-Resistant Design: Prevents unauthorized removal from bracket without a tool.
  • Clear Visual Indication: Two LEDs provide 360-degree visible alarm and power status indication.
  • CE and RoHS Certified: Meets international safety and environmental standards.
  • Compact Installation: Diameter of 4.0 inches (103 mm) fits standard ceiling mounts.

Product Images of Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System

Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System pictures & photos
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System pictures & photos
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System pictures & photos
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System pictures & photos
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System pictures & photos
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System pictures & photos
Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
  • Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
  • Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
    Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
  • Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
    Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
  • Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
    Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
  • Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
    Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
  • Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
    Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
  • Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System
    Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System

Find Similar Products

Product Description

INSTALLATION AND MAINTENANCE INSTRUCTIONS


Conventional Photoelectric Smoke Sensors
SPECIFICATIONS
Operating Voltage Range:        9 to 28VDC Volts Non-polarized
Standby Current:                ≤60µA @ 24 VDC
Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC
Operating Humidity Range:        10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range:    14°F to 122°F (-10°C to50°C)
Adjustable Sensitivity:             1.06±.26%FT.
Height:                        2.2˝ (55 mm) installed in Base
Diameter:                        4.0˝ (103 mm)
Weight:                        5.5 oz. (155 g)

INSTALLATION





Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System



 

BEFORE INSTALLING
NOTICE: This manual should be left with the owner/user of this equipment.
IMPORTANT: The detector must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year.
GENERAL DESCRIPTION
The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.

1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.






Fire Panel 2 Wire Conventional Smoke Alarm Smoke Detector for Fire Alarm System



Figure 1. Wiring diagram:

Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.





Dust covers are an effective way to limit the entry of dust into smoke detector sensing chambers. However, they may not completely prevent airborne dust particles from entering the detector. Therefore, We recommends the removal of detectors before beginning construction or other dust producing activity.
Be sure to remove the dust covers from any sensors that were left in place during construction as part of returning the system to service.

TAMPER-RESISTANCE
The detector includes a tamper-resistant capability that prevents their removal from the bracket without the use of a tool.
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the operating voltage range?
The device operates within a voltage range of 9 to 28VDC.
How do I install the smoke detector?
Wire the sensor base per the diagram, install the sensor into the base by turning clockwise, apply power, and test the sensor.
Can the detector be removed without a tool?
No, the detector includes a tamper-resistant capability that prevents removal without a tool.
How often should the detector be cleaned?
The detector should be cleaned at least once a year following NFPA 72 requirements.
What happens if the sensitivity is out of limit?
The LEDs will turn off to indicate a trouble condition when sensitivity is outside the listed limit.
Is the device compatible with conventional fire alarm panels?
Yes, it is designed to be used with most conventional fire alarm control panels.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now