2 Wire Conventional Heat Detector Wt105

Type: Smoke Alarm
Usage: Temperature
Installation Mode: Ceiling Mounted
Certification: CE, RoHS
Application: Home, Communication Electronic Products
Weight: 155g
Samples:
US$ 8.2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
WT105
Color
White
Reading Type
Electronic Code
Voltage
15-28V
Line
2 Wire
Transport Package
Carton
Specification
102*102*50mm
Trademark
heat detector
Origin
China
HS Code
8531100000
Production Capacity
50000/Month

Product Description

WT105 Conventional Heat Detector

1. GENERAL DESCRIPTION
The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is
applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel. Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.


2. SPECIFICATIONS

Operating Voltage Range:    15 to 28VDC Volts Non-polarized
Standby Current:  40μA @ 24 VDCMaximum
Alarm Current (LED on:)  ≤30mA@ 24 VDC
Fixed Temperature Rating:    135°F (57°C)
Temperatures:  14°F to 122°F (-10°C to50°C)
Operating Humidity Range:  10% to 93% Relative Humidity Non-condensing
Height:    55 mm installed in Base
Diameter:     103 mm
Weight: 5.5 oz. (155 g)Installation
 

3. INSTALLATION
NOTE: All wiring must conform to applicable local codes,
ordinances, and regulations.
INSTALL THE DETECTOR BASE
1. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in accordance with the fire
standard in your country.
2. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto an electrical
junction box such as an octagonal (75mm, 90mm or 100mm), a round (75mm), or a square (100mm) box
without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the wires on the terminals, 


4. Terminals functions description:
Terminal 2: IN+( Zone Input+)
Terminal 5: IN- (Zone Input- )
Terminal 6: IN+( Zone Output+)
Terminal 5: IN- (Zone Output- )
Terminal 6: Remote Indicator+
Terminal 3: Remote Indicator

 

2 Wire Conventional Heat Detector Wt105
 