Home Alarm System Conventional Fire Alarm System Control Smoke Detector Smoke Sensor
Contact Supplier
Product Highlights
- Three-Year Limited Warranty: Covers defects in materials and workmanship for 3 years from manufacture date.
- Photoelectric Sensing Technology: Uses state-of-the-art optical sensing chamber for reliable smoke detection.
- Tamper-Resistant Design: Prevents unauthorized removal from bracket without a specialized tool.
- Dual LED Alarm Indication: Provides 360-degree visible alarm with flashing status and latching alarm light.
- CE and EN54 Certified: Meets strict European safety and performance standards for fire alarms.
Product Attributes
- Customization
- Available
- Type
- Smoke Alarm
- Usage
- Alarm
- Model NO.
- CSD81
- Installation Mode
- Ceiling Mounted
- Certification
- CE, En54
- Application
- Home, Communication Electronic Products
- Weight
- 155g
- Smoke Sensitivity
- 0.12 to 0.25dB/M
- Standby Current
- 24VDC
- Operating Voltage
- Zero 10 Degree to 50degree
- Type Wire
- Conventional Wire
- Transport Package
- Carton
- Specification
- 103*103*55mm
- Trademark
- ALARM
- Origin
- China
- HS Code
- 85319010
- Production Capacity
- 500000/Month
Product Images of Home Alarm System Conventional Fire Alarm System Control Smoke Detector Smoke Sensor
Find Similar Products
Product Description
|
INSTALLATION AND MAINTENANCE INSTRUCTIONS
Conventional Photoelectric Smoke Sensors SPECIFICATIONS Operating Voltage Range: 9 to 28VDC Volts Non-polarized Standby Current: ≤60µA @ 24 VDC Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: 14°F to 122°F (-10°C to50°C) Adjustable Sensitivity: 1.06±.26%FT. Height: 2.2˝ (55 mm) installed in Base Diameter: 4.0˝ (103 mm) Weight: 5.5 oz. (155 g) INSTALLATION
BEFORE INSTALLING NOTICE: This manual should be left with the owner/user of this equipment. IMPORTANT: The detector must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year. GENERAL DESCRIPTION The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. INSTALLATION NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct. Remove power from initiating-device circuits before installing detectors. 1. Wire the sensor base per the wiring diagram, Figure 1. 2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place. 3. After all sensors have been installed, apply power to the control unit. 4. Test the sensor(s) as described in the TESTING section of this manual. 5. Notify the proper authorities that the system is in operation. Figure 1. Wiring diagram: ![]() Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out. Dust covers are an effective way to limit the entry of dust into smoke detector sensing chambers. However, they may not completely prevent airborne dust particles from entering the detector. Therefore, We recommends the removal of detectors before beginning construction or other dust producing activity. Be sure to remove the dust covers from any sensors that were left in place during construction as part of returning the system to service. TAMPER-RESISTANCE The detector includes a tamper-resistant capability that prevents their removal from the bracket without the use of a tool. TESTING Before testing, notify the proper authorities that the smoke detector system is undergoing maintenance and will temporarily be out of service. Disable the zone or system undergoing maintenance to prevent unwanted alarms. Detectors must be tested after installation and as part of periodic maintenance. NOTE: Before testing the detector, check to ensure the LEDs blink. If they do not, the detector has lost power (check the wiring), it is defective (return it for repair), or the detector sensitivity is outside the listed limits. The sensor can be tested in the following ways: Smoke Entry test: Aerosol Generator (Gemini 501) The GEMINI model 501 aerosol generator can be used for smoke entry testing. Set the generator to represent 4%/ft to 5%/ft obscuration as described in the GEMINI 501 manual. Using the bowl shaped applicator, apply aerosol until the panel alarms. A sensor that fails any of these tests should be cleaned as described under CLEANING, and retested. If the sensor fails after cleaning, it must be replaced. When testing is complete, restore the system to normal operation and notify the proper authorities that the system is back in operation. CLEANING Before removing the detector, notify the proper authorities that the smoke detector system is undergoing maintenance and will be temporarily out of service. Disable the zone or system undergoing maintenance to prevent unwanted alarms.
THREE-YEAR LIMITED WARRANTY We warrants its enclosed smoke detector to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. We makes no other express warranty for this smoke detector. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company's obligation of this Warranty shall be limited to the repair or replacement of any part of the smoke detector which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning Convoy Security's technical support number for a Return Authorization number, send defective units postage prepaid to Convoy Security local representative office. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company's negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. FCC STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause Harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which th |
|
![]() ![]() |
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- What is the warranty period for this smoke detector?
- The product comes with a three-year limited warranty covering defects in materials and workmanship from the date of manufacture.
- How do I test the smoke detector?
- You can test the detector using an aerosol generator (like Gemini 501) to introduce smoke, or by checking if the LEDs blink. If they do not, check wiring or replace the unit.
- What is the operating voltage range?
- The detector operates within a voltage range of 9 to 28VDC.
- How often should the detector be cleaned?
- The detector should be cleaned at least once a year to ensure proper operation and remove dust from the sensing chamber.
- Can this detector be used in dusty environments?
- Dust covers can help limit dust entry, but they do not completely prevent it. It is recommended to remove detectors during construction or dust-producing activities.
- What happens if the detector sensitivity is out of limits?
- If sensitivity is outside the listed limits, the LEDs will turn off to indicate a trouble condition, and the unit may need cleaning or replacement.
- Is the installation wiring polarized?
- No, the operating voltage range is non-polarized, allowing for flexible wiring connections.
- What are the dimensions of the smoke detector?
- The installed height is 2.2 inches (55 mm) and the base diameter is 4.0 inches (103 mm).
Send your message to this supplier
People who viewed this also viewed
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$62.00-75.00 / Piece
-
US$3.50-5.80 / Piece
-
US$3.80-5.80 / Piece
-
US$2.50-3.60 / Piece
-
US$2.60-3.60 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Conventional Fire Alarm System
- Conventional Smoke Detetors
- Home Alarm System Conventional Fire Alarm System Control Smoke Detector Smoke Sensor
Related Categories
Hot Searches
- Fire Alarm Factories
- Alarm Security Factories
- Fire Alarm System Factories
- Alarm Product
- Fire Security Alarm
- Smoke Alarm Sensor
- Alarm Detector Smoke Sensor
- CE Fire Smoke Alarm
- Smoke Detector Fire Alarm System
- Smoke Alarm System Bulkbuy
