Product Highlights

  • High Volume Alarm: Features an 85dB alarm horn and flashing red LED for clear warnings at 3 meters.
  • Self-Diagnostic System: MCU intelligent software provides continuous self-diagnostics for reliability.
  • Flexible Installation: Mounts high for methane or low for propane with included sturdy metal bracket.
  • Wide Voltage Range: Operates on AC90-270VAC with low power consumption of less than 1.5W standby.
  • Relay Output Control: Outputs relay signals to control electric valves or alarms upon gas detection.
  • Compact Design: Small dimensions (122x76x38mm) ideal for homes, commercial properties, and RVs.
  • Silence Function: Test button silences alarm for 4 minutes before automatically resetting.

Product Images of Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator

Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator pictures & photos
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator pictures & photos
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator pictures & photos
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator pictures & photos
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator pictures & photos
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator pictures & photos
Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
  • Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
  • Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
    Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
  • Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
    Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
  • Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
    Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
  • Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
    Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
  • Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
    Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
  • Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
    Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator

Find Similar Products

Product Description

 

General

The gas detector is designed for single station use or for connecting to fire alarm or security alarm panel. Small and compact, the design and color makes it ideal for use in the home, small commercial properties, and recreational vehicles. It is intended to detect leakage of natural gas (methane gas), town gas, and bottled gas (propane gas), coal gas. The unit is designed for AC Powered plug-in applications. The gas detector can bemounted high (for methane gas) or low (for propane (LPG) gas). It is equipped with a sturdy metal mounting bracket for quick, easy, and secure installation.

Key Specifications/Special Features

  • Detect all sorts of combustible gases, natural gas (methane), bottled gas (propane), LPG (Liquefied petroleum Gas), LNG (Liquefied natural gas), coal gas, including town gas.
  • Easy to install, mounting bracket included.
  • Loud 85dB alarm and LED warning light.
  • High quality durable sensor.
  • Self diagnostic function by MCU intelligent software.
  • Excellent reliability & High stability.
  • Ideal for all kitchens.

TECHNICAL SPECIFICATIONS
Unit Dimensions:122mm (H) x 76 mm (W) x 38 mm (D)
Color: Ceiling White
Operating Temperature: -10°C to +50°C
Ambient Humidity: ≤95% RH
Alarm Horn: 85dB at 3m (10 feet)
Operating Voltage: AC90-270VAC
Power Consumption: <1.5W (Standby), <5W (Alarm)
Value of Detection Threshold (Lower Explosive Limit):
Natural Gas: 7500ppm (15%LEL)
LPG: 2000ppm (10%LEL)
Coal Gas: 800ppm (2%LEL)
Method of Alarm: Flashing Red LED with 85dB alarm
Warm Up Time: approximately 60 Seconds
Alarm Output: Relay Output (2A@DC24V, 1A@220VAC)
Accessories: Metal mounting bracket
Mounting screws with anchors

 OPERATION AND TESTING
Check and test the gas detector after installation. It should be tested weekly and check after re-occupation following a holiday.

  1. Power Up: After turn on the power, the Green Power LED is on, buzzer beep once and the Yellow LED flashes. The unit would take approximately 45 Seconds to warm up. After warm up, the Yellow LED stop flash and the buzzer beep twice. In the warm up time, the unit doesn't response to any operation until end of the warm up period. It's forbidden to test detector during the warm up period.
  2. Normal: When the unit is in normal status, the Green Power LED is on, and Yellow LED is off, Power LED flashes every 3 seconds.
  3. Fault: When the sensor is in the fault status, the sensor Yellow LED is on, the buzzer beep (0.5s ON/3s OFF). The unit will restore to normal status after the fault has been corrected.
  4. Alarm: While detecting the gas leaking reach the alarm level, the sensor Red Alarm LED would turn on and the buzzer sound. while the unit's will output relay contacts output(relay output module), or output signal for electric valve or electric hand. (See Figure2).
  5. Test: In the normal status, Press the test button and the unit should sound and the all LED light, no signals output. To ensure the gas detector is working, you should test it weekly.
  6. Silence: In the alarm status, press Test button, the unit enter the silence status, the sound silenced and the red LED flashes quickly, about 4 minutes late, the unit exit the silence status.
Press test button again to exit the silence status.
  1. Reset: In the alarm status, press the Test button down and hold above 5 seconds, the unit would restore to normal status

TESTING AND MAINTENANCE
WEEKLY TESTING
Push and hold the Test button on the cover until a loud alarm sounds. The alarm sequence should last for 5-6 seconds. If the Detector ever fails to test properly, replace it immediately.
REGULAR MAINTENANCE
To keep the Detector in good working order:
  1. Test it every week using the Test button.
  2. Vacuum the detector cover at least twice a year, using the soft brush. Test the detector again after vacuuming.

 GAS SAFETY GUIDE
  1. If you hear the gas alarm sound or suspect that there is a gas leakage. You should open all windows and doors to allow the gas to disperse.
  2.  Don't switch on lighting, press door bell, exhausting fan or any kind of electrical appliance to avoid explosion. Check all the gas appliances. Extinguish any naked flames and turn off the gas control off the gas supply.
  3. Call the Fire department immediately outside your home or premises/ apartment.
  4. If you are on holiday, turn off appliances switches & the gas control valve.
  5. Do not place the bed near gas pipes or gas meter.
  6. Do not change the location of gas pipes by yourself.
  7. In order to ensure your home safety, please employ registered installers for regular safety inspection of all gas installation & appliances.

 

Natural Gas Leakage Tester Combustible Gas Detector with Mechanical Valve Manipulator
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

How loud is the alarm sound?
The alarm volume is 85dB at a distance of 3 meters (10 feet).
How often should I test the detector?
You should test the detector weekly using the test button to ensure it is working properly.
Can I mount this detector on the ceiling?
Yes, it can be mounted high for methane gas or low for propane gas using the included metal bracket.
What is the operating voltage range?
The unit operates on AC90-270VAC and consumes less than 1.5W in standby mode.
What should I do if the gas alarm sounds?
Open windows and doors, do not switch on electrical appliances, extinguish flames, and call the fire department immediately.
How long does the warm-up time take?
The unit takes approximately 60 seconds to warm up after power is turned on.
Does the detector have a self-diagnostic feature?
Yes, it is equipped with MCU intelligent software for self-diagnostic functions to ensure high stability.

Send your message to this supplier