Wholesale Factory Price Good Microprocessor Conventional Fire Alarm Control Panel
Contact Supplier
Product Highlights
- Four Style B IDCs: Supports four initiating device circuits accepting two-wire smoke detectors and normally-open contacts.
- Built-in NAC Circuit: Includes one Style Y notification appliance circuit for alarm, trouble, and supervisory signals.
- High Volume Alarm: Alarm volume reaches at least 100dB within 1 meter for effective warning.
- Wide Voltage Range: Operates on primary AC power from 90V to 270VDC for stable performance.
- CE Certified: Meets European safety and performance standards for fire alarm systems.
- Compact Design: Weighs only 7kg with a red finish, suitable for various installation environments.
- Relay Protection: Features Form-C relays with reverse polarity protection for system safety.
- Flexible Wiring: Supports sub-line system wiring mode with 485/232 receive frequency options.
Product Attributes
- Customization
- Available
- Type
- Fire Alarm Host
- Function
- Networked
- Model NO.
- Ck1004
- Usage
- Fire, Smoke
- Certification
- CE
- Alarm Volume (within 1m)
- ≥100dB
- Networking Mode
- Alarm
- Receive Frequency
- 485/232
- Wiring Mode
- Sub-Line System
- Weight
- 7kg
- Color
- Red
- Number of Zones
- 4
- Primary AC
- 90-270VDC
- Standby Battery
- 2*12V
- Transport Package
- Carton
- Specification
- 37*440*100mm
- Trademark
- panel
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 500000/Month
Product Images of Wholesale Factory Price Good Microprocessor Conventional Fire Alarm Control Panel
Find Similar Products
Product Description
|
Conventional Fire Alarm Control Panel with four Zones Key Specifications/Special Features |
|
Such a system, however, does not assure protection against property damage or loss of life resulting from a fire.
The Manufacturer recommends that smoke and/or heat detectors be located throughout a protected premise following the recommendations of the current edition of the National Fire Protection Association Standard 72 (NFPA 72), manufacturer's recommendations, State and local codes, and the recommendations contained in the Guide for Proper Use of System Smoke Detectors, which is made available at no charge to all installing dealers. A study by the Federal Emergency Management Agency (an agency of the United States government) indicated that smoke detectors may not go off in as many as 35% of all fires. While fire alarm systems are designed to provide early warning against fire, they do not guarantee warning or protection against fire. A fire alarm system may not provide timely or adequate warning, or simply may not function, for a variety of reasons:
Smoke detectors may not sense fire where smoke cannot reach the detectors such as in chimneys, in or behind walls, on roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level or floor of a building. A second-floor detector, for example, may not sense a first-floor or basement fire.
Particles of combustion or "smoke" from a developing fire may not reach the sensing chambers of smoke detectors be- cause:
- Barriers such as closed or partially closed doors, walls, or chimneys may inhibit particle or smoke flow.
- Smoke particles may become "cold," stratify, and not reach the ceiling or upper walls where detectors are located.
- Smoke particles may be blown away from detectors by air outlets.
- Smoke particles may be drawn into air returns before reaching the detector.
Smoke detectors, even when working properly, have sensing limitations. Detectors that have photo electronic sensing chambers tend to detect smoldering fires better than flaming fires, which have little visible smoke. Detectors that have ionizing-type sensing chambers tend to detect fast-flaming fires better than smoldering fires. Because fires develop in different ways and are often unpredictable in their growth, neither type of detector is necessarily best and a given type of detector may not provide adequate warning of a fire.
Smoke detectors cannot be expected to provide adequate warning of fires caused by arson, children playing with matches (especially in bedrooms), smoking in bed, and violent explosions (caused by escaping gas, improper storage of flammable materials, etc.).
Heat detectors do not sense particles of combustion and alarm only when heat on their sensors increases at a predetermined rate or reaches a predetermined level. Rate-of-rise heat detectors may be subject to reduced sensitivity over time. For this reason, the rate-of-rise feature of each detector should be tested at least once per year by a qualified fire protection specialist. Heat detectors are designed to protect property, not life.
IMPORTANT! Smoke detectors must be installed in the same room as the control panel and in rooms used by the system for the connection of alarm transmission wiring, communications, signaling, and/or power. If detectors are not so located, a developing fire may damage the alarm system, crippling its ability to report a fire.
Audible warning devices such as bells may not alert people if these devices are located on the other side of closed or partly open doors or are located on another floor of a building. Any warning device may fail to alert people with a disability or those who have recently consumed drugs, alcohol or medication. Please note that:
- Strobes can, under certain circumstances, cause seizures in people with conditions such as epilepsy.
- Studies have shown that certain people, even when they hear a fire alarm signal, do not respond or comprehend the meaning of the signal. It is the property owner's responsibility to conduct fire drills and other training exercise to make people aware of fire alarm signals and instruct them on the proper reaction to alarm signals.
- In rare instances, the sounding of a warning device can cause temporary or permanent hearing loss.
Equipment used in the system may not be technically compatible with the control. It is essential to use only equipment listed for service with your control panel.
Telephone lines needed to transmit alarm signals from a premise to a central monitoring station may be out of service or temporarily disabled. For added protection against telephone line failure, backup radio transmission systems are recommended.
The most common cause of fire alarm malfunction is inadequate maintenance. To keep the entire fire alarm system in excellent working order, ongoing maintenance is required per the manufacturer's recommendations, and UL and NFPA standards. At a minimum, the requirements of Chapter 7 of NFPA 72 shall be followed. Environments with large amounts of dust, dirt or high air velocity require more frequent maintenance. A maintenance agreement should be arranged through the local manufacturer's representative. Maintenance should be scheduled monthly or as required by National and/ or local fire codes and should be performed by authorized professional fire alarm installers only. Adequate written records of all inspections should be kept.
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- What is the alarm volume level?
- The alarm volume is at least 100dB within 1 meter.
- How many zones does this panel support?
- It supports four zones with four Style B Initiating Device Circuits.
- What is the operating voltage range?
- The primary AC input range is 90V to 270VDC.
- Does this product have CE certification?
- Yes, the product is CE certified.
- What is the weight of the control panel?
- The weight of the panel is 7kg.
- What is the standby battery configuration?
- It uses two 12V batteries for standby power.
- What is the lead time for orders?
- Peak season lead time is one month, while off-season is within 15 workdays.
- What payment terms are accepted?
- We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
Send your message to this supplier
People who viewed this also viewed
-
US$25.00-35.00 / Piece
-
US$155.00-170.00 / Piece
-
US$550.00-680.00 / Set
-
US$135.00-170.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-50.00 / Piece
-
US$50.00-60.00 / Piece
-
US$130.00-170.00 / Piece
-
US$50.00-75.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Conventional Fire Alarm System
- Others Conventional Fire Alarm System
- Wholesale Factory Price Good Microprocessor Conventional Fire Alarm Control Panel
Related Categories
Hot Searches
- Fire Alarm Factories
- Alarm Security Factories
- Home Alarm Factories
- Alarm Systems Factories
- Home Security Products Alarm
- Fire Security Alarm
- Electric Alarm Home Security
- Security Alarm Panel
- Smoke Alarm Security
- Fire Protection Panel Bulkbuy