High Temperature Wire Linear Heat Detector for Energy and Chemical Industry

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Multi-Type Flexibility: Offers Conventional, Outdoor, Chemical Resistance, and Explosion Proof types for diverse industrial needs.
  • FM & CE Certified: Complies with FM and CE standards, with UL/cUL listed spacing options for global compliance.
  • Digital Precision: MS1000 interface provides digital output with local fire/fault indication and low-power design.
  • Versatile Installation: Suitable for ceiling or side wall mounting in warehouses, workshops, and high-risk flammable areas.
  • Robust Protection: Strong protective outer jacket prevents damage, suitable for harsh industrial environments.

Product Images of High Temperature Wire Linear Heat Detector for Energy and Chemical Industry

High Temperature Wire Linear Heat Detector for Energy and Chemical Industry pictures & photos
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry pictures & photos
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry pictures & photos
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry pictures & photos
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry pictures & photos
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry pictures & photos
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
  • High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
    High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
  • High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
    High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
  • High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
    High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
  • High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
    High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
  • High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
    High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
  • High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
    High Temperature Wire Linear Heat Detector for Energy and Chemical Industry

Find Similar Products

Product Description

here are multiple types of LHD, Conventional Type, Outdoor Type, High performance of Chemical Resistance Type and Explosion Proof Type, each type has its own feature and applications. Please choose the right type according to the factual situation.
Description of matching electrical equipments
MS1000 is digital type LHD with comparatively simple output signal. And Shenyang P.T.S. sales matching electrical equipments to MS1000.

MS1000-I
Linear Detector Interface
1.Interface for MS1000, MS1000-CR,MS1000-OD and MS1000-EP digital linear heat cable
With local fire and fault indication Fire and fault relay output available
Low-power design
Metal case
Technical Specifications
Operating Voltage:24VDC
 Operating Voltage Range: 16VDC-28VDC
Operating Current: Standby Current:≤20mA
                   Fire Current:≤30mA
                   Fault Current:≤25mA
Operating environment: Temperature:-45ºC-60ºC
                        Relative humidity:95%
IP Rating :Ip66
Dimensions:90mm × 85mm × 52mm(L×W×H)

MS1000-P  
End of Line Unit
End of Line Unit for MS1000, MS1000-CR,MS1000-OD and MS1000-EP digital linear heat cable
The functions are balancing the signal status
For Digital linear heat cable monitoring and alarm/fault  simulating
(Notice: "Fire Test" pushbutton is for testing use only)
Technical Specifications
Operating Voltage: No Electronics
Operating environment: Temperature:-45ºC-60ºC
                        Relative humidity:95%
IP Rating :IP66
Dimensions:90mm×85mm×52mm(L×W×H)  

The consumers can choose other electrical equipments to connect with MS1000, making good preparation as followed:
(1)Analysing the protection capability of the equipments(input terminal). For during the operating, the LHD may couple the signal of the protected device(power cable),causing voltage surge or current impact to the input terminal of the connecting equipment.
(2)Analysing the anti-EMI capability of the equipments(input terminal). Because long-length use of LHD during the operation, there may be power frequency or radio frequency from LHD itself interfering the signal.
(3)Analysing what is the maximum length of LHD  the equipments can connect.
This analysis should depend on the technical parameters of MS1000, which will be introduced in detail later in this manual.
If any other queries relating, please contact us for more information. Our engineers will provide technical support.
Connecting instruction  
  1. Connecting drawing of MS1000-I ( Drawing 1)
 
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
 
(Drawing 1)
  1. C1 C2:with sensor cable, non-polarized connection
  2. A  B:with DC24V power,non-polarized connection
  3. COM NC:fault output
  4. COM NO:fire alarm output (resistance value in fire alarm ≤50Ω)
  1. Connecting drawing of MS1000-P ( Drawing 2)
 
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
 


(Drawing 2)
  1. C1 C2:with sensor cable, non-polarized connection
  2. XT2 : connected with 4.7k terminal resistance
Installation requirement
The linear heat detector is a type of fire detector with advanced functions, which meet all kinds of fire protection requirements in any inflammable sites. Though the detector has strong protective outer jacket to prevent damage, more attention should be paid during the installation due to the partial and internal damage cannot be found immediately. The damaged cable may cause the alarm of system malfunction or alarm during the future use. As a result, the followings should be paid attention to:
1. Forbid heavy objects overwhelming the heat sensing cable;
2. Forbid bending or turning the heat sensing cable with an acute angle;
3. Prevent corrosion;
4. Forbid using nonstandard accessories on the linear heat cable.
5. "Fire Test" pushbutton on the End of Line Unit is for testing use only,  it must be restricted to prevent accidental or mistaken use.
It comes to different fire detecting results due to different methods of installation, so we need take all the following factors into consideration, including the height, the structure, the obstruction, the air flow and so on, to prevent improper installation adversely affecting the normal use of the detector.

The  installation spacing of LHD
Characteristic features of LHD makes itself become the best choice of fire alarm system  for applications in high risk of flammable areas, major types of industrial and commercial places, especially in some harsh environments where spot-type detectors cannot be installed.
The LHD of Shenyang P.T.S has been widely applied in industrial warehouses, workshops, etc. The detector can be installed at the ceiling level or the side wall depending on the features of the protected device, getting the same detecting result as the spot-type detectors'.  

How to determine the installation spacing?
There are different instructions from UL and FM standards, according to their own test requirements, the detector should match the figures below:
Model Approvals/Max. Listed Spacing
FM UL/cUL
MS1000  68ºC
MS1000-CR  68ºC
MS1000-OD  68ºC
MS1000-EP  68ºC
7.7m
 
15.2m
MS1000  88ºC
MS1000-CR  88ºC
MS1000-OD  88ºC
MS1000-EP  88ºC
7.7m
 
15.2m
MS1000  105ºC
MS1000-CR  105ºC
MS1000-OD  105ºC
MS1000-EP  105ºC
4.5m 15.2m
MS1000  138ºC
MS1000-CR  138ºC
MS1000-OD  138ºC
MS1000-EP  138ºC
4.5m 15.2m
MS1000  180ºC
MS1000-CR  180ºC
MS1000-OD  180ºC
MS1000-EP  180ºC
N/A
Special applications
N/A
Special applications
But the figures above are for reference only, it is rather difficult to determine the practical installation spacing of the LHD, for we can not predicate the information of the fire, such as area, size, location and heat quantity. Furthermore, the LHD detect the fire temperature normally through the air radiation, it is more difficult to gain an accurate spacing data of LHD installation. We should design and lay the LHD with practice, properly reduce the spacing among the LHD to guarantee the accurate fire alarm. 5m spacing among LHDs is the best distance to get good detecting performance on our experience.

We should design and lay the LHD with practice, properly reduce the spacing among the LHD to guarantee the accurate fire alarm. 5m spacing among LHDs is the best distance to get good detecting performance on our experience.
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
High Temperature Wire Linear Heat Detector for Energy and Chemical Industry
 

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What types of Linear Heat Detectors are available?
We offer Conventional Type, Outdoor Type, High Performance Chemical Resistance Type, and Explosion Proof Type to suit different application scenarios.
How should the Linear Heat Detector be installed?
It can be installed on ceilings or side walls. Avoid heavy loads, acute bending, corrosion, and nonstandard accessories. 5m spacing is recommended for optimal performance.
What is the recommended installation spacing for the detector?
While FM/UL standards list specific spacings (e.g., 7.7m or 15.2m), we recommend a practical spacing of 5m to guarantee accurate fire alarm detection in real-world conditions.
What electrical equipment is compatible with this detector?
It is compatible with the MS1000 digital interface, MS1000-I interface, and MS1000-P End of Line Unit. Other equipment must be analyzed for protection and anti-EMI capabilities.
What certifications does this product hold?
The product holds CE and FM certifications, with specific models listed under UL/cUL standards for various temperature ratings.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now