Syria Fire Safety Use Addressable Fire Alarm System

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High Reliability: Designed for small and medium projects with powerful functions and flexible configuration.
  • LCD Display: 128x64 lattice graphic LCD monitor displays alarms, faults, and operations.
  • Built-in Printer: Prints all information on fire alarms, faults, and various operations.
  • Large Capacity: One-loop control panel supports a maximum of 240 devices.
  • High Alarm Volume: Alarm volume is at least 80dB within 1 meter.
  • RoHS Certified: Meets RoHS certification standards for safety and environmental compliance.
  • Flexible Wiring: Supports 485/232 networking and sub-line system wiring modes.
  • Dual Power Supply: Operates on 220VAC with 2x12V/12AH standby battery backup.

Product Images of Syria Fire Safety Use Addressable Fire Alarm System

Syria Fire Safety Use Addressable Fire Alarm System pictures & photos
Syria Fire Safety Use Addressable Fire Alarm System
Syria Fire Safety Use Addressable Fire Alarm System pictures & photos
Syria Fire Safety Use Addressable Fire Alarm System
Syria Fire Safety Use Addressable Fire Alarm System pictures & photos
Syria Fire Safety Use Addressable Fire Alarm System
Syria Fire Safety Use Addressable Fire Alarm System pictures & photos
Syria Fire Safety Use Addressable Fire Alarm System
Syria Fire Safety Use Addressable Fire Alarm System pictures & photos
Syria Fire Safety Use Addressable Fire Alarm System
Syria Fire Safety Use Addressable Fire Alarm System pictures & photos
Syria Fire Safety Use Addressable Fire Alarm System
  • Syria Fire Safety Use Addressable Fire Alarm System
    Syria Fire Safety Use Addressable Fire Alarm System
  • Syria Fire Safety Use Addressable Fire Alarm System
    Syria Fire Safety Use Addressable Fire Alarm System
  • Syria Fire Safety Use Addressable Fire Alarm System
    Syria Fire Safety Use Addressable Fire Alarm System
  • Syria Fire Safety Use Addressable Fire Alarm System
    Syria Fire Safety Use Addressable Fire Alarm System
  • Syria Fire Safety Use Addressable Fire Alarm System
    Syria Fire Safety Use Addressable Fire Alarm System
  • Syria Fire Safety Use Addressable Fire Alarm System
    Syria Fire Safety Use Addressable Fire Alarm System

Find Similar Products

Product Description



FW6000 Fire Alarm Control Panel


FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed by our company for applications in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices.

Note: COM port needs grounding
1,(Monitoring Start Output)HJ: Active NO terminal to Fire alarm routing device (use jumper to switch  
between passive and active), which will close to connect +24V output after started (each points with a
max output current of 100mA)
2,(Monitoring Start Output)SG: Active NO terminal to Sounder Strobe (Both active and passive modes,  
use jumper to switch between passive and active), which will close to connect +24V output after
started (with max output current of 100mA for each direct-start point)
3,BUS: Non-polarity two-wire bus terminal
4,Linkage power supply output: 24VDC(Max output current 1A)
5,Main board power supply input: 220VAC
6,Grounding Terminal: Grounding

2.4 Technical Specifications
2.4.1 Power Supply:
AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC)
Standby Battery: 2 x 12V/12AH
2.4.2 Operating Environment:
Temperature: 0ºC~+40ºC
Relative Humidity: ≤95%, non-condensing
2.4.3 Capacity: One loop with maximum 240 devices
2.4.4 Display: LCD 128×64 lattice graphic
2.4.5 Dimension: (Length ×Width ×Height):330.0mm×130.0mm×400.0mm
2.4.6 Wiring requirement
1,Recommend to use RVS2×1.0mm2 or RVS2×1.5mmtwisted wire for CAN communication wire and bus   
wire, while use RVSP2×1.0mm2 at the high interference environment.
2,Not allowed to lay CAN communication wire and telephone line together with bus wire inside the same        
   multi-core cable.
 
Syria Fire Safety Use Addressable Fire Alarm System
 

Syria Fire Safety Use Addressable Fire Alarm System
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the maximum capacity of the FW6000?
The FW6000 is a one-loop control panel with a maximum capacity of 240 devices.
Does the panel have a built-in printer?
Yes, it is equipped with a built-in printer to print out alarm and fault information.
What are the power supply requirements?
It requires 220VAC nominal voltage and includes a standby battery of 2x12V/12AH.
What is the alarm volume level?
The alarm volume is at least 80dB within a distance of 1 meter.
Is the system networked?
No, this model is a non-networked fire alarm host with 485/232 connectivity options.
What is the lead time for orders?
Peak season lead time is one month, while off-season lead time is within 15 workdays.
What payment methods are accepted?
Accepted payment terms include LC, T/T, D/P, PayPal, Western Union, and small-amount payments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now