En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm

Product Details
Customization: Available
Type: Smoke Alarm
Usage: Smoke
Still deciding? Get samples of US$ 8.2/Piece
Request Sample
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
7
Year of Establishment
2012-07-20
  • En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
  • En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
  • En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
  • En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
  • En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
  • En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
Find Similar Products

Basic Info.

Model NO.
TC5161
Installation Mode
Ceiling Mounted
Certification
CE
Application
Home, Industry, Communication Electronic Products
Weight
120g
Color
White
Line
2 Wire
Read Type
Electronic Code
Alarm Type
LED
Transport Package
Carton
Specification
110*110*30MM
Trademark
alarm
Origin
China
HS Code
8531100000
Production Capacity
500000/Month

Product Description

JTY-GM-TC5161 Addressable Photoelectric Smoke Detector (Detector) uses infrared scattering
technology. With novel structure and attractive appearance, the detector has stable and reliable performance
and high damp-proof ability. It is suitable for restaurants, hotels, office buildings, school buildings,
warehouses, power plants, etc.
II Features
1. The detector can be addressed in field by using Hand Held Programmer, easy and reliable for
commissioning.
2. Single chip uses real-time sampling and data processing system.
3. Temperature and humidity drift compensation, dust accumulation degree and fault detection.
4. Non-polarized signal 2-wire.
III Technical Specifications
III Technical Specifications
1. Operating voltage
Signal bus voltage: loop 24V (18.5V~26V)
2. Operating current
Standby current: ≤ 0.3mA
Alarm current: ≤ 0.8mA
3. Indicator
Red. Flashes when polling, and illuminates in alarming.
4. Programming method
Electronically programming (code range: one address within 1~255)
5. Wiring
Non-polarized signal 2-wire
6. Operating environment
Temperature: -10°C~+55°C
Relative Humidity: ≤95%, non-condensing
7. Dimension
Diameter: 100mm Height: 51mm (with base)
8. Ingress protection rating: IP23
9. Material and color of enclosure: ABS; milky white
IV Structure and Operation Principle
1. Appearance of the detector is shown in Fig. 1.
2. Operation principle
The detector uses infrared scattering technology; the smoke density can be detected. The detector
receives very weak infrared light under normal smokeless condition. If smoke particles enter the chamber,
the received light signal will increase by scattering. When smoke density reaches a pre-set level, the detector
will alarm out. In order to reduce interference and power consumption, the emitting circuit works in pulse
mode to prolong the life of IR LED. It is cooperating with TC addressable fire alarm control panels to build
a fire detection system.
En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
Mounting and Wiring
1.   Mounting
Installation of the detector is shown in Fig. 2.En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
2. Base of the detector is shown in Fig. 3. There are 2 conductor pieces with terminals on the base.
Detector's loop should be respectively connected with two terminals (polarity-insensitive).After the base
is fixed firmly, rotate the bottom of detector and base clockwise, and then the detector will be fitted to
the base.
En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
. 3.Recommended Wiring
1.0mm2 or above fire cable, subject to local codes.
4. Warning: Before installing the detector, please cut off power and make sure all bases fixed firmly.
VI Testing
1. The detector must be tested after installation and periodical maintenance.
2. Testing content:
1). Registration: After confirming the installation and wiring is correct, register devices to the fire alarm
control panel, and check whether the numbers of installed detectors and registered detectors are
consistent.
2). Fire simulation test: After registration, choose one detector arbitrarily, and fit it to meet fire 
conditions to check whether the detector generates fire normally.
3). After testing, reset the detector. Notify the proper authorities that the system returns to normal state.
4). Clean the failure detector in the test according to Maintenance, and test it again. If it is still fail to
pass, please return it to repair.
3. Warning: Before testing, please ensure that the detector has been installed correctly and powered up.
En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm

 

En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm
En54 Lpcb Approved Addressable Fire Smoke Detector for Detect Smoke and Alarm

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier