Conventional Fire Alarm Control Panel System 2-18 Zones for Fire Alarm Project

Type: Fire Alarm Host
Function: Networked
Usage: Fire, Smoke
Certification: CE
Alarm Volume (within 1m): ≥100dB
Networking Mode: Alarm
Samples:
US$ 75/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
CP1002
Receive Frequency
485/232
Wiring Mode
Sub-Line System
Weight
7kg
Color
Red
Number of Zones
4
Primary AC
90-270VDC
Standby Battery
2*12V
Transport Package
Carton
Specification
37*440*100mm
Trademark
panel
Origin
China
HS Code
8531100000
Production Capacity
500000/Month

Product Description

EXTERNAL (KEYSWITCH OPERATED) 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders

INTERNAL 

• One Man Detector Test 

• Zone isolate 

• Revert to short circuit = fire (no resistors in call points)

 

EXTERNAL INDICATORS 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders
 

INTERNAL INDICATORS 

• Open circuit zone fault 

• Short circuit zone fault 

• Zone isolate 

• Engineer test selected

 

Conventional Fire Alarm Control Panel System 2-18 Zones for Fire Alarm Project
 


OUTPUTS

Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)

Ancillary connections for expansion modules will allow the following:

1.Repeater panels

2.Multiple sounder outputs

3.Connection to landlord panel
 

Input Voltage AC 100-240V, 50/60Hz
Internal Power Supply DC 30V 3A
Total Output Current ≤200mA @ 220V
Chipset 32-bit Micro processor
Zone 1-8 Zone(s)
Max Number of Smoke Detector per Zone 20-25 pcs
 
Capacity High EMI Immunity
Backup Battery DC 12V/2.2AH * 2 (not include)
Dimension 325x265x100mm
Operating Temperature 0ºC ~ +50ºC
Weight(Without battery) 2700g
Material  Iron