Type: Smoke Alarm
Signal Transmission: Wired Alarm
Working Mode: Passive
Application: Indoor, Outdoor
Working Principle: Electro-Optical Type
Transmission Mode: Cable
Samples:
US$ 6.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
SG6008
Alarm Volume (within 1m)
≥80dB
Receive Frequency
Alarm System
Coclor
Red
Power
DC6V to 27V
Volume at 24V and 3m
75dB-110dB
Wiring Method
Two-Wire Bus (Non-Polarized)
Operating Current(Min)
5mA
Transport Package
Carton
Specification
100*45.5mm
Trademark
Alarm
Origin
China
HS Code
8531100000
Production Capacity
50000/Momth

Product Description

Features
  • Ultra low power consumption with non-polarized two wire bus.
  • Professional microchip provides highest reliability.
  • Adopt super bright LED and special structure buzzer to achieve high luminance and high sound pressure.
  • Visual or audible visual mode setting freely.
  • Each detector has a unique detector ID at the back.
  • Electrically addressed, can be modified online or by a programmer.
  • Chute designed to ease installation.
Technical Specifications
Operating Voltage Range DC6V to 27V
Monitoring Current(Max) 0.2mA
Operating Current(Min) 5mA
Volume at 24V and 3m 75dB-110dB
Change cycle 2.Os-4.Os
Flash rate
Maximum loop length
Temperature Range
Humidity
1.0Hz -1.5Hz
5km (based on ZR-RVS-2*1.5mm2)
-10 °C ~+55 °C
<95% rel. (non-condensing)
Sensor Base J-SCM08
Protection Category IP30
Dimensions( XH) 100.0x45.5mm (including base)
Wiring method two-wire bus (non-polarized)

Installation
Surface mounted, in the normal space, height 2.2m above the ground is appropriate.
  • Fix the base (determine the installation direction according to the mark T") on the embedded junction box or the mounting location with the M4 screw.
  • Adopt ZR-RVS-2*1.5mm2 twisted pair to respectively run through the entrance holes in the base and polarity-indiscriminately connect to the S+ and S- terminals.
  • Set address (1 to 200) on the detector by programmer.
  • Install the VAD on the base.
Wiring
"S+" and "S." are the bus terminals connected to the Fire alarm control Panel(F.A.C.P.).Fire Alarm System Horns/Sirens/Sounders/Buzzers with Flashing Strobe Light
Fire Alarm System Horns/Sirens/Sounders/Buzzers with Flashing Strobe Light
Fire Alarm System Horns/Sirens/Sounders/Buzzers with Flashing Strobe Light
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now