Factory Price Fire Alarm Extinguishant Control Panel Easy Use

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • EN54 & EN12094 Certified: Complies with European standards EN54-2, EN54-4, and EN12094-1 for safety and reliability.
  • 4-Zone Networked System: Features four detection zones capable of contributing to the extinguishant release decision.
  • Flexible Delay Control: Allows extinguishing signal delay up to 75 seconds for alarm verification before evacuation.
  • Multiple Safety Outputs: Includes voltage-free relay contacts for fire/local fire and monitoring via low pressure switch.
  • Manual Override Mode: Supports manual-only mode to disable automatic extinguishant release via detection devices.
  • Robust Power Supply: Integral mains-powered battery charger and power supply designed for 230V/50Hz operations.

Product Images of Factory Price Fire Alarm Extinguishant Control Panel Easy Use

Factory Price Fire Alarm Extinguishant Control Panel Easy Use pictures & photos
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
Factory Price Fire Alarm Extinguishant Control Panel Easy Use pictures & photos
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
Factory Price Fire Alarm Extinguishant Control Panel Easy Use pictures & photos
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
Factory Price Fire Alarm Extinguishant Control Panel Easy Use pictures & photos
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
Factory Price Fire Alarm Extinguishant Control Panel Easy Use pictures & photos
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
Factory Price Fire Alarm Extinguishant Control Panel Easy Use pictures & photos
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
  • Factory Price Fire Alarm Extinguishant Control Panel Easy Use
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use
  • Factory Price Fire Alarm Extinguishant Control Panel Easy Use
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use
  • Factory Price Fire Alarm Extinguishant Control Panel Easy Use
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use
  • Factory Price Fire Alarm Extinguishant Control Panel Easy Use
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use
  • Factory Price Fire Alarm Extinguishant Control Panel Easy Use
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use
  • Factory Price Fire Alarm Extinguishant Control Panel Easy Use
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use

Find Similar Products

Product Description


The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing system and has four detection zones, any or all of which are capable of contributing to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.

In addition to the requirements of EN54-2 the control panel has the following facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes. EN54-2 Section 10 option with requirements

Delay of the actioning of fire alarm devices (sounders) so that an alarm may be verified before a premises is evacuated. EN54-2 Section 7.11 option with requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises upon the detection of a fire condition or the operation of a manual call point.  EN54-2 Section 7.8 option with requirements

In addition to the requirements of EN54-2, all control panels have voltage free relay contacts for fire and local fire which operate upon a fire condition. These are to be used for local control and signaling.

In addition to the requirements of EN12094-1 the control panel has the following facilities:
Delay of extinguishing signal of up to 75 seconds. EN12094-1 Section 4.17 option with requirements.

Signal representing the flow of extinguishing agent to indicate the released condition. EN12094-1 Section 4.18 option with requirements.

Monitoring of the status of components by way of a low pressure switch input.  EN12094-1 Section 4.19 option with requirements.
Emergency hold device to enable the extinguishant delay time to be extended. EN12094-1 Section 4.20 option with requirements.

Control of flooding time to deactivate the releasing output after a set period of time. EN12094-1 Section 4.21 option with requirements.

Manual only mode to disable the release of extinguishant via automatic detection devices. EN12094-1 Section 4.23 option with requirements.

Triggering of equipment outside the system by way of first and second stage contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements

Activation of alarm devices with different signals to indicate pre-discharge and released warnings using different sounds. EN12094-1 Section 4.30 option with requirements.

2. Safety
Suppliers of articles for use at work are required under section 6 of the Health and Safety at Work act 1974 to ensure as reasonably as is practical that the article will be safe and without risk to health when properly used.
An article is not regarded as properly used if it is used 'without regard to any relevant information or advice' relating to its use made available by the supplier.
This product should be installed, commissioned and maintained by trained service personnel in accordance with the following:

(i) IEE regulations for electrical equipment in buildings
(ii) Codes of practice
(iii) Statutory requirements
(iv) Any instructions specifically advised by the manufacturer

According to the provisions of the Act you are therefore requested to take such steps as are necessary to ensure that you make any appropriate information about this product available to anyone concerned with its use.
This equipment is designed to operate from 230V/50Hz mains supplies and is of class 1 construction.  As such it must be connected to a protective earthing conductor in the fixed wiring of the installation and a readily accessible double pole disconnect device meeting the requirements of EN60950/IEC950 which disconnects live and neutral simultaneously shall  be incorporated in the fixed wiring.
Switch disconnect devices such as MK Sentry 63A or similar are suitable for this.
Failure to ensure that all conductive accessible parts of this equipment are adequately bonded to the protective earth will render the equipment unsafe.
This control panel is environmental class A and is designed for indoor use only at temperatures between -50ºC(+/- 3) and +400ºC (+/- 2) and with a maximum relative humidity of 95%.
The IP rating for the enclosure is IP30.
Operation outside of these limits may render the equipment unsafe.

Conventional Fire Fighting Panel

Key Specifications/Special Features

  • Four Style B (Class B) Initiating Device Circuits (IDCs).
  • All zones accept two-wire smoke detectors and any normally-open contact devices.
  • One built-in Fire Fighting Ouput.
  • 24-volt operation.
  • Resettable four-wire smoke detector power @ 500 mA.
  • Non-resettable power @ 500 mA.
  • One-man walk-test programmable for silent or audible test.
  • Disable/Enable control per IDC.
  • Reverse polarity protection.
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use
    Factory Price Fire Alarm Extinguishant Control Panel Easy Use
     
 
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
 
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
Factory Price Fire Alarm Extinguishant Control Panel Easy Use
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What certifications does this control panel have?
The panel is designed in accordance with European standards EN54-2, EN54-4, and EN12094-1.
How many detection zones are supported?
The control panel supports four detection zones, any or all of which can contribute to the release decision.
Can the extinguishing delay be adjusted?
Yes, the panel allows a delay of the extinguishing signal of up to 75 seconds for verification purposes.
Is manual control available?
Yes, it features a manual only mode to disable the release of extinguishant via automatic detection devices.
What is the power supply requirement?
The equipment operates from 230V/50Hz mains supplies and includes an integral battery charger.
What is the IP rating of the enclosure?
The IP rating for the enclosure is IP30, suitable for indoor environments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now