DC12-24V Manual Fire Alarm Call Point Price Break Glass for Emergency Door Call Point
Contact Supplier
Product Highlights
- Break Glass Activation: Reports fire or emergency by pressing the breakable glass for immediate alarm.
- Key Reset Capability: Can be reset using a test key without breaking the glass, ensuring convenience.
- Wide Voltage Compatibility: Operates on 9 to 28VDC with 10-30mA current at 24VDC for stable performance.
- Compact Wall Mount Design: Dimensions 88x88x50mm, includes base for easy surface mounting on walls.
- CE Certified Safety: Meets CE certification standards for use in homes and electronic products.
- Robust Material Build: Constructed from ABS & PC material in yellow color for durability.
- Standard Resistance: Features 470 Ohm alarm resistance compatible with conventional panels.
Product Attributes
- Customization
- Available
- Type
- Smoke Alarm
- Usage
- Call Point
- Model NO.
- SB106
- Installation Mode
- Wall Mounted
- Certification
- CE
- Application
- Home, Communication Electronic Products
- Operating Voltage Range
- 9 to 28VDC
- Operating Degree Range
- -10℃ to 50 ℃
- Alarm Resistance
- 470Ω
- Color
- Yellow
- Marerial
- ABS & PC
- Transport Package
- Carton
- Specification
- 188*88*50mm
- Trademark
- fire
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 500000/Month
Product Images of DC12-24V Manual Fire Alarm Call Point Price Break Glass for Emergency Door Call Point
Find Similar Products
Product Description
![]() |
Alarm Current 10 to 30 mA @ 24 VDC
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
Input terminal Wire Gauge: 12 to 18 AWG
Dimensions: Length 88mm, Width 88mm, Depth 50mm
Weight: Net Weight 172g, Gross Weight 185g
Loop Design and Wiring The fire alarm control panel Zone wire can be connected to terminal 2(+),4(-). And there is a 5.1V Zener diode should be connected to terminal 1A and 4A.(included by default). If the manual call point is in the end of the zone wire, a 5.6K resistance should be connected to terminal 2, 4. INSTALLATION NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. Mounting Indoor Wall 1. Attach mounting base to wall at 1.5 meter's high. 2. Connect field wiring to terminals 3. To attach product to mounting base. 4. Secure product by tightening the one mounting screws in the front of the product housing. Figure 1. Install and Wiring diagram: ![]() |
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- How do I reset the call point without breaking the glass?
- You can reset the manual call point using a test key without breaking the glass.
- What is the operating voltage range?
- The operating voltage range is 9 to 28VDC, with an alarm current of 10 to 30 mA at 24 VDC.
- What materials is the device made of?
- The device is made of ABS & PC material and is available in yellow color.
- What are the dimensions and weight?
- Dimensions are 88mm (L) x 88mm (W) x 50mm (D). Net weight is 172g, gross weight is 185g.
- Is this compatible with conventional fire alarm panels?
- Yes, it is compatible with all conventional fire alarm control panels and features 470 Ohm resistance.
- What is the installation method?
- It is designed for wall-mounted installation with an included base and requires mounting screws.
- What certifications does this product have?
- The product holds CE certification, suitable for home and communication electronic product applications.
Send your message to this supplier
People who viewed this also viewed
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$62.00-75.00 / Piece
-
US$3.50-5.80 / Piece
-
US$3.80-5.80 / Piece
-
US$2.50-3.60 / Piece
-
US$2.60-3.60 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Conventional Fire Alarm System
- Conventional call point
- DC12-24V Manual Fire Alarm Call Point Price Break Glass for Emergency Door Call Point
Related Categories
Hot Searches
- Fire Alarm Factories
- Alarm Security Factories
- Alarm Control System Factories
- Fire Alarm System Factories
- Fire Alarm Panel
- Fire Alarm Control
- Fire Alarm Control System
- Fire Alarm Home
- CE Fire Smoke Alarm
- Emergency Break Galss Bulkbuy