Fire Alarm Control Panel of Public System Control Panel for Smart Home Security
Contact Supplier
Product Highlights
- CE Certified: Product meets CE safety and compliance standards for fire detection.
- Networked Functionality: Supports 485/232 networking modes for integrated security systems.
- Multiple Zone Options: Available in 2, 4/6, 8, 10, 12, 14, 16, or 18 zone configurations.
- Comprehensive Fault Monitoring: Monitors open/short circuits, battery failure, and detector removal.
- Flexible Power Supply: Operates on 230V AC mains with 27V DC internal supply and backup.
- Expandable System: Supports repeater panels, multiple sounder outputs, and landlord connections.
- Robust Construction: Durable enclosure with dimensions 415 x 265 x 100mm and gray finish.
Product Attributes
- Customization
- Available
- Type
- Fire Alarm Host
- Function
- Networked
- Model NO.
- CP1018
- Usage
- Fire, Smoke
- Certification
- CE
- Alarm Volume (within 1m)
- ≥100dB
- Networking Mode
- Alarm
- Receive Frequency
- 485/232
- Wiring Mode
- Sub-Line System
- Weight
- 5kg
- Color
- Gray
- Number of Zones
- 18
- Primary AC
- 90-270VDC
- Standby Battery
- 2*12V
- Transport Package
- Carton
- Specification
- 325x265x100mm
- Trademark
- panel
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 500000/Month
Product Images of Fire Alarm Control Panel of Public System Control Panel for Smart Home Security
Find Similar Products
Product Description
The fire panel must be sited internally, in an area
where it is readily accessible by staff on duty and the
fire brigade. The area should be clean and dry and
you should take into account any likelihood of
tampering or vandalism. The ambient light and
sound levels should allow the status of the indicators
to be clearly seen and the internal sounder to be
heard. Full details can be found in BS 5839: Pt1: 1988:
Section 15.3 "Fire Detection and Alarm Systems for
Buildings".
External (key-switch operated):
- Reset/resound/test zone lamps evacuate
- Silence alarm sounders
- Silence fault sounders
Internal:
- One man detector test
- Zone isolate
- Revert to short-circuit: fire (no resistors in call points)
External indicators:
- Sounder fault
- Battery/power supply fault
- Mains on
- Zone fire
- Zone fault
Internal indicators:
- Open circuit zone fault
- Short circuit zone fault
- Zone isolated
- Engineer test selected
Outputs:
- Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)
Ancillary connections for expansion modules will allow the following:
- Repeater panels
- Multiple sounder outputs
- Connection to landlord panel

Specifications
| 2 (0.8A supply) | 4 / 6 (1.5A supply) | 8/10/12/14/16/18 (4.0A supply) |
|
| Power specifications | |||
| Mains supply voltage | 230±10%V AC, 50/60Hz | 230±10%V AC, 50/60Hz | 230±10%V AC 50/60Hz |
| Internal power supply | 27V DC | 27V DC | 27V DC |
| Total output current limited to | 800mA at 240V AC | 1500mA at 240V AC | 4000mA at 240V AC |
| Auxiliary power output | 27V DC | 27V DC | 27V DC |
| Mains supply monitored for failure | Yes | Yes | Yes |
| Battery charger monitored for failure | Yes | Yes | Yes |
| Batteries monitored for disconnection and failure | Yes | Yes | Yes |
| Detector circuit specification | |||
| Number of circuits | 2 | 4 or 6 | 8, 10, 12, 14,16,or 18 |
| Line fault monitored for open circuit | Yes | Yes | Yes |
| Line fault monitored for short circuit | Yes (can be disabled) | Yes (can be disabled) | Yes (can be disabled) |
| Line fault monitored for detector removal | Yes, if end of line monitor unit fitted in place of end of line resistor | ||
| End of line resistor (supplied) value | 6.8K Ohm, 5% tolerance, 0.25W | 6.8K Ohm, 5% tolerance, 0.25W | 6.8K Ohm, 5% tolerance, 0.25W |
| Detector continuity diodes | Silicone 1N4001 or Schottky type (required if end of line monitor unit fitted to give detector removal fault) | ||
| Call point resistor value (not supplied) | 470 to 680 Ohm, 0.5W | 470 to 680 Ohm, 0.5W | 470 to 680 Ohm, 0.5W |
| Maximum number of smoke detectors per zone | 20 (maximum detector current = 2mA) | 20 (maximum detector current = 2mA) | 20 (maximum detector current = 2mA) |
| Maximum number of manual call points per zone | No limit | No limit | No limit |
| Sounder circuit specifications: | |||
| Number of circuits | 2 | 2 | 2 |
| End of line resistor value | 6.8K Ohm, 5% tolerance, 0.25W | 6.8K Ohm, 5% tolerance, 0.25W | 6.8K Ohm, 5% tolerance, 0.25W |
| Line fault monitored for open circuit | Yes | Yes | Yes |
| Line fault monitored for short circuit | Yes | Yes | Yes |
| Outputs fused at | 1A | 1A | 1.6A |
| Maximum total output current all outputs | 800mA | 1500mA | 4000mA |
| Maximum no of bells at 25mA each bell | 32 | 56 | 120 |
| Maximum no of electronic sounders at 20mA | 40 | 70 | 150 |
| Auxiliary relay contacts (do not connect mains voltages) | 1A 30V DC max voltage free |
1A 31V DC max voltage free |
1A 32V DC max voltage free |
| Fuses-all fuses compliant to ice (EN60127 PT2) | |||
| Mains terminal block | 200mA/T 20mm | 400mA/T 20mm | 630mA/T 20mm |
| Sounder outputs | 1A/F 20mm | 1A/F 20mm | 1.6A/F 20mm |
| Auxiliary output | 1A/F 20mm | 1A/F 20mm | 1A/F 20mm |
| Battery fuse | 1.6A/F 20mm | 1.6A/F 20mm | 3A/F 20mm |
| Door retaining magnets | do not use panel power supply as you will drastically reduce battery standby time | ||
| Connection block | |||
| Largest acceptable | 2.5mm2 | 2.5mm2 | 2.5mm2 |
| Smallest acceptable conductor size | 0.75mm2 | 0.75mm2 | 0.75mm2 |
| Dimensions | |||
| Enclosure (width x height x depth) | 415 x 265 x 100mm | 415 x 265 x 100mm | 415 x 265 x 100mm |
| Weight (without batteries) | 5100g | 5200g | 5500 |
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- What are the available zone configurations?
- The panel supports various configurations including 2, 4 or 6, and 8 through 18 zones depending on the model.
- How loud is the alarm sounder?
- The alarm volume is at least 100dB when measured within 1 meter of the device.
- Does the system monitor for faults?
- Yes, it monitors for line faults (open/short circuit), battery disconnection, and detector removal.
- Can the system be expanded?
- Yes, it supports ancillary connections for expansion modules, repeater panels, and multiple sounder outputs.
- What is the maximum number of detectors per zone?
- Each zone can support a maximum of 20 smoke detectors with a maximum current of 2mA each.
- What are the dimensions of the enclosure?
- The enclosure dimensions are 415mm (width) x 265mm (height) x 100mm (depth).
- Is the product CE certified?
- Yes, the fire alarm control panel holds CE certification for safety compliance.
Send your message to this supplier
People who viewed this also viewed
-
US$25.00-35.00 / Piece
-
US$550.00-680.00 / Set
-
US$155.00-170.00 / Piece
-
US$135.00-170.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-50.00 / Piece
-
US$50.00-60.00 / Piece
-
US$25.00-35.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Conventional Fire Alarm System
- Others Conventional Fire Alarm System
- Fire Alarm Control Panel of Public System Control Panel for Smart Home Security
Related Categories
Hot Searches
- Fire Alarm Factories
- Alarm Security Factories
- Fire Alarm System Factories
- Home Alarm Factories
- Alarm Control Security
- Home Security Products Alarm
- Fire Security Alarm
- CE Home Security Alarm
- Electric Alarm Home Security
- Fire Protection Panel Bulkbuy