• High Reliability Fire Alarm System in Fire Alarm Smoke Detector
  • High Reliability Fire Alarm System in Fire Alarm Smoke Detector
  • High Reliability Fire Alarm System in Fire Alarm Smoke Detector
  • High Reliability Fire Alarm System in Fire Alarm Smoke Detector
  • High Reliability Fire Alarm System in Fire Alarm Smoke Detector
  • High Reliability Fire Alarm System in Fire Alarm Smoke Detector

High Reliability Fire Alarm System in Fire Alarm Smoke Detector

Type: Smoke Detectors
Anti-theft Alarm System Approach: Active
Anti-Theft Alarm System Type: Sound and Light Alarm
Anti-Theft Alarm System-Wide: Point Control Alarm Detectors
Anti-Theft Alarm System Distance: Common Detectors
Types of Smoke Detectors: Photoelectric Smoke Style
Samples:
US$ 450/Set 1 Set(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
FW6000
Infrared Sensor Probe Type
Smoke
Infrared Sensor Installation
Ceiling
Combustible Gas Detector Model
Smoke Senor
Mounted
Wall Mounted
AC Power
220V
Standby Battery
2*12V/12ah
Temperature
Zero Degree to 40 Degree
Display
LCD 128*64 Lattice Graphic
Weight
8kg
Transport Package
Carton
Specification
330*120*400MM
Trademark
Alarm
Origin
China
HS Code
8531100000
Production Capacity
50000/Momth

Product Description

Installation and Operation Manual

FW6000 Fire Alarm Control Panel


FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed by our company for applications in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices.

Note: COM port needs grounding
1,(Monitoring Start Output)HJ: Active NO terminal to Fire alarm routing device (use jumper to switch  
between passive and active), which will close to connect +24V output after started (each points with a
max output current of 100mA)
2,(Monitoring Start Output)SG: Active NO terminal to Sounder Strobe (Both active and passive modes,  
use jumper to switch between passive and active), which will close to connect +24V output after
started (with max output current of 100mA for each direct-start point)
3,BUS: Non-polarity two-wire bus terminal
4,Linkage power supply output: 24VDC(Max output current 1A)
5,Main board power supply input: 220VAC
6,Grounding Terminal: GroundingHigh Reliability Fire Alarm System in Fire Alarm Smoke Detector
 
2.4 Technical Specifications
2.4.1 Power Supply:
AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC)
Standby Battery: 2 x 12V/12AH
2.4.2 Operating Environment:
Temperature: 0ºC~+40ºC
Relative Humidity: ≤95%, non-condensing
2.4.3 Capacity: One loop with maximum 240 devices
2.4.4 Display: LCD 128×64 lattice graphic
2.4.5 Dimension: (Length ×Width ×Height):330.0mm×130.0mm×400.0mm
2.4.6 Wiring requirement
1,Recommend to use RVS2×1.0MM2 or RVS2×1.5MM twisted wire for CAN communication wire and bus   
wire, while use RVSP2×1.0mm2 at the high interference environment.
2,Not allowed to lay CAN communication wire and telephone line together with bus wire inside the same        
   multi-core cable.

High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector
High Reliability Fire Alarm System in Fire Alarm Smoke Detector


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now