• Automatic Extinguisher Control Panel Extinguisher System
  • Automatic Extinguisher Control Panel Extinguisher System
  • Automatic Extinguisher Control Panel Extinguisher System
  • Automatic Extinguisher Control Panel Extinguisher System
  • Automatic Extinguisher Control Panel Extinguisher System
  • Automatic Extinguisher Control Panel Extinguisher System

Automatic Extinguisher Control Panel Extinguisher System

Type: Fire Alarm Host
Function: Networked
Usage: Fire, Smoke
Certification: CE
Alarm Volume (within 1m): ≥100dB
Networking Mode: Alarm
Samples:
US$ 249/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
CM1004
Receive Frequency
485
Wiring Mode
Sub-Line System
Weight
5kg
Color
Red/Gray
Number of Zones
4
Primary AC
90-270VDC
Power Supply Rating
3 AMPS@24VDC
Transport Package
Carton
Specification
37*440*100mm
Trademark
panel
Origin
China
HS Code
8531100000
Production Capacity
500000/Month

Product Description

Automatic Extinguisher Control Panel Extinguisher System
 

AUTOMATIC EXTINGUISHER CONTROL PANEL Conventional Fire Fighting Panel 
 Introduction
The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices.

The control equipment is a combined fire alarm control panel and extinguish ing system and has three detection zones, any or all of which are capable of contributing to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.
In addition to the requirements of EN54-2 the control panel has the following facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes. EN54-2 Section 10 option with requirements
Delay of the actioning of fire alarm devices (sounders) so that an alarm may be verified before a premises is evacuated. EN54-2 Section 7.11 option with requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises upon the detection of a fire condition or the operation of a manual call point.  EN54-2 Section 7.8 option with requirements
In addition to the requirements of EN54-2, all control panels have voltage free relay contacts for fire and local fire which operate upon a fire condition. These are to be used for local control and signaling.
In addition to the requirements of EN12094-1 the control panel has the following facilities:
Delay of extinguishing signal of up to 60 seconds. EN12094-1 Section 4.17 option with requirements.
Signal representing the flow of extinguishing agent to indicate the released condition. EN12094-1 Section 4.18 option with requirements.
Monitoring of the status of components by way of a low pressure switch input.  EN12094-1 Section 4.19 option with requirements.
Emergency hold device to enable the extinguishant delay time to be extended. EN12094-1 Section 4.20 option with requirements.
Control of flooding time to deactivate the releasing output after a set period of time. EN12094-1 Section 4.21 option with requirements.
Manual only mode to disable the release of extinguishant via automatic detection devices. EN12094-1 Section 4.23 option with requirements.
Triggering of equipment outside the system by way of first and second stage contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements
Activation of alarm devices with different signals to indicate pre-discharge and released warnings using different sounds. EN12094-1 Section 4.30 option with requirements.
Automatic Extinguisher Control Panel Extinguisher System

Automatic Extinguisher Control Panel Extinguisher System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.