Fashion Addressable Fire Alarm System Input Module Smoke Detector

Product Details
Customization: Available
Type: Sensor
Usage: Alarm
Still deciding? Get samples of US$ 7.5/Piece
Request Sample
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
7
Year of Establishment
2012-07-20
  • Fashion Addressable Fire Alarm System Input Module Smoke Detector
  • Fashion Addressable Fire Alarm System Input Module Smoke Detector
  • Fashion Addressable Fire Alarm System Input Module Smoke Detector
Find Similar Products

Basic Info.

Model NO.
M-6006
Installation Mode
Wall Mounted
Application
Home, Communication Electronic Products
Weight
53G
Color
Rice Yellow
Temperature
Zero Ten Degree to 50 Degree
Power
15-28V
Read Type
Electronic Code
Transport Package
Carton
Specification
56*56*22mm
Trademark
module
Origin
China
Production Capacity
500000/Month

Product Description

Instruction manual of M-6006 input module

A. Features

1.Installed directly in the embedded box
2.Built-in product ID code
3.Using hardware and software filtering technology to improve the module's anti-jamming capability
4.Linkage,  2 bus type,nonpolarity

B. Specifications

1.Working voltage: linkage 15-28V Impulse voltage
2.Working current:
   1)Standby current:≤0.55mA
   2)action current:≤5.5mA
3. Type:Addressable, 2 wire(nonpolarity)
4. Encoding: Electronic code
5. Module's Indication status:
   1)Normal monitoring status:The green inspection lamp flashes periodically
   2)action state: red action light keep lit, green inspection lights keep lit
6. Operating environment: Temperature-10ºC~50ºC Relative humidity≤95%RH,No condensation
7.  Dimensions :56mm×56mm×21.5mm(transparent cover not included)
8. Color: beige
9. Weight: about 53g(transparent cover included)
10. Executive standard:GB 16806-2006

C. Structural features

1.Module's Dimensions and installation dimensions shown in Figure 1

Figure 1 M-6006 Dimensions and installation dimensionsFashion Addressable Fire Alarm System Input Module Smoke Detector
 

D. Installation

WARNING: Before installing the device, the power must be switched off.
  1. The module can be installed in either a exposed way or a concealed installation. As for concealed installation, the module can be installed in the 86H50 standard embedded box, and then installed on the cover just like Figure 2 shows; for exposed way, the module installed in the terminal box which shown in Figure 3.

      
Figure 2 concealed wire diagram                 Figure 3 exposed wire diagramFashion Addressable Fire Alarm System Input Module Smoke Detector


2. wiring method shows in Figure 4Fashion Addressable Fire Alarm System Input Module Smoke Detector


Figure 4: M-6006 wiring diagram
3. Wire requirements: Wire (bus) should be RVS-2 * 1.0 mm2 or 1.5 mm2; RVS-2*1.0 mm2 or 1.5 mm2 for signal input wire.


E. Use and operation
Encoding operation: you can use our company's hand-held encoder M-6006 to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242, the address code for the same loop is unique). Press the "write code" button, if encoding is successful, the encoder will display the address number after sending the address code. If failed, the encoder will display "FAL" after sending the address code.
For details on the steps and methods of encoding, refer to the "M-6006 Handheld Encoder User's Manual".
.

F. Note

1. The alarm function test of smoke detector should be performed every six months.
2. When the controller detects the cleaning forecast, please send the number of smoke detectors back to the company for cleaning, in order to avoid false or false positives, resulting in unnecessary losses.




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier