Addressable Heat Detector in Fire Extinguisher for Alarm System

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Advanced Coding Technology: Uses electronic code technology for flexible address assignment ranging from 1 to 242.
  • High Anti-Interference: Hardware and software filtering significantly improve resistance to interference.
  • Fast Response Speed: Highly sensitive thermal elements ensure rapid temperature detection response.
  • Clear Status Indication: LED provides distinct visual signals for normal, fire, and failure statuses.
  • Easy Installation: Designed for standard 86H50 embedded boxes with simple clockwise rotation mounting.

Product Images of Addressable Heat Detector in Fire Extinguisher for Alarm System

Addressable Heat Detector in Fire Extinguisher for Alarm System pictures & photos
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System pictures & photos
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System pictures & photos
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System pictures & photos
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System pictures & photos
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System pictures & photos
Addressable Heat Detector in Fire Extinguisher for Alarm System
  • Addressable Heat Detector in Fire Extinguisher for Alarm System
    Addressable Heat Detector in Fire Extinguisher for Alarm System
  • Addressable Heat Detector in Fire Extinguisher for Alarm System
    Addressable Heat Detector in Fire Extinguisher for Alarm System
  • Addressable Heat Detector in Fire Extinguisher for Alarm System
    Addressable Heat Detector in Fire Extinguisher for Alarm System
  • Addressable Heat Detector in Fire Extinguisher for Alarm System
    Addressable Heat Detector in Fire Extinguisher for Alarm System
  • Addressable Heat Detector in Fire Extinguisher for Alarm System
    Addressable Heat Detector in Fire Extinguisher for Alarm System
  • Addressable Heat Detector in Fire Extinguisher for Alarm System
    Addressable Heat Detector in Fire Extinguisher for Alarm System

Find Similar Products

Product Description

Instruction manual of H-6002 heat detector  

A. Features

1.Built-in product ID code
2.Using hardware and software filtering to improve the anti-interference ability of the temperature detector
3.2 bus, linkage type,nonpolarity
4.Advanced electronic code technology improves the flexibility of coding
5. Using highly sensitive thermal elements to improve the response speed of temperature sensor.

B. Specifications

Working voltage 15-28V Impulse voltage
Working current Standby current ≤0.5mA
Alarm current ≤3.0mA
Type 2 bus(nonpolarity)
Encoding Electronic code
Temperature detector's status indication Normal monitoring status LED light will blink periodically
Fire status remain lit
Failure status LED light remain off or blink irregularly
Operating environment Temperature-10ºC~50ºC, Relative humidity≤90%RH no condensation
Color white
.Weight 120g
Executive standard GB 4716-2005

C. Outline diagram

(Figure 1)


Figure 1:H-6002 Dimensions  

Addressable Heat Detector in Fire Extinguisher for Alarm System


 

D. Installation

1.Installation method
Figure 2 shows the installation of the temperature detector


   
Figure 2 H-6002 installation diagram
Addressable Heat Detector in Fire Extinguisher for Alarm System

86H50 standard embedded box can be used as pre-embedded box; when installation, locate heat detector on the base and rotate clockwise.

2. Wiring requirements: Wire should be RVS-2 * 1.0 mm2 or 1.5 mm2
3. WARNING: Before installing the heat detector, turn off the power and make sure that all the bases are installed securely.

E. Use and operation
Encoding operation: you can use our company's hand-held encoder p6010 to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242, the address code for the same loop is unique). Press the "write code" button, if encoding is successful, the encoder will display the address number after sending the address code. If failed, the encoder will display "FAL" after sending the address code.
For details on the steps and methods of encoding, refer to the P6010  Handheld Encoder User's Manual".
.

F. Note

1. The plastic part attached with heat detector is dust cover. Please cover the dust cover after the installation or room decoration, painting construction, so that the smoke detectors are contaminated.
2. The alarm function test of smoke detector should be performed every six months.
3. When the controller detects the cleaning forecast, please send the number of smoke detectors back to the company for cleaning, in order to avoid false or false positives, resulting in unnecessary losses.

Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
Addressable Heat Detector in Fire Extinguisher for Alarm System
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the working voltage range?
The working voltage is 15-28V.
How many address codes can be assigned?
The address code range is 1-242, and each code on the same loop must be unique.
How is the product encoded?
You can use the P6010 handheld encoder for live coding by connecting clips to the terminals and pressing the write code button.
What are the wiring requirements?
Wire should be RVS-2 * 1.0 mm2 or 1.5 mm2.
How often should the alarm function be tested?
The alarm function test should be performed every six months.
What is the purpose of the dust cover?
The plastic dust cover should be placed after installation or decoration to prevent contamination of the detector.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now