Addressable Heat Detector in Fire Extinguisher for Alarm System
Contact Supplier
Product Highlights
- Advanced Coding Technology: Uses electronic code technology for flexible address assignment ranging from 1 to 242.
- High Anti-Interference: Hardware and software filtering significantly improve resistance to interference.
- Fast Response Speed: Highly sensitive thermal elements ensure rapid temperature detection response.
- Clear Status Indication: LED provides distinct visual signals for normal, fire, and failure statuses.
- Easy Installation: Designed for standard 86H50 embedded boxes with simple clockwise rotation mounting.
Product Attributes
- Customization
- Available
- Type
- Heat
- Usage
- Temperature
- Model NO.
- H6002
- Installation Mode
- Ceiling Mounted
- Application
- Home, Communication Electronic Products
- Weight
- 120g
- Color
- White
- Reading Type
- Electronic Code
- Voltage
- 15-28V
- Line
- 2 Wire
- Transport Package
- Carton
- Specification
- 102*102*50mm
- Trademark
- heat detector
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 50000/Month
Product Images of Addressable Heat Detector in Fire Extinguisher for Alarm System
Find Similar Products
Product Description
A. Features
1.Built-in product ID code2.Using hardware and software filtering to improve the anti-interference ability of the temperature detector
3.2 bus, linkage type,nonpolarity
4.Advanced electronic code technology improves the flexibility of coding
5. Using highly sensitive thermal elements to improve the response speed of temperature sensor.
B. Specifications
| Working voltage | 15-28V Impulse voltage | |
| Working current | Standby current | ≤0.5mA |
| Alarm current | ≤3.0mA | |
| Type | 2 bus(nonpolarity) | |
| Encoding | Electronic code | |
| Temperature detector's status indication | Normal monitoring status | LED light will blink periodically |
| Fire status | remain lit | |
| Failure status | LED light remain off or blink irregularly | |
| Operating environment | Temperature-10ºC~50ºC, Relative humidity≤90%RH no condensation | |
| Color | white | |
| .Weight | 120g | |
| Executive standard | GB 4716-2005 | |
C. Outline diagram
(Figure 1)Figure 1:H-6002 Dimensions
D. Installation
1.Installation methodFigure 2 shows the installation of the temperature detector
Figure 2 H-6002 installation diagram
86H50 standard embedded box can be used as pre-embedded box; when installation, locate heat detector on the base and rotate clockwise.
2. Wiring requirements: Wire should be RVS-2 * 1.0 mm2 or 1.5 mm2
3. WARNING: Before installing the heat detector, turn off the power and make sure that all the bases are installed securely.
E. Use and operation
Encoding operation: you can use our company's hand-held encoder p6010 to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242, the address code for the same loop is unique). Press the "write code" button, if encoding is successful, the encoder will display the address number after sending the address code. If failed, the encoder will display "FAL" after sending the address code.
For details on the steps and methods of encoding, refer to the P6010 Handheld Encoder User's Manual".
.
F. Note
1. The plastic part attached with heat detector is dust cover. Please cover the dust cover after the installation or room decoration, painting construction, so that the smoke detectors are contaminated.2. The alarm function test of smoke detector should be performed every six months.
3. When the controller detects the cleaning forecast, please send the number of smoke detectors back to the company for cleaning, in order to avoid false or false positives, resulting in unnecessary losses.
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- What is the working voltage range?
- The working voltage is 15-28V.
- How many address codes can be assigned?
- The address code range is 1-242, and each code on the same loop must be unique.
- How is the product encoded?
- You can use the P6010 handheld encoder for live coding by connecting clips to the terminals and pressing the write code button.
- What are the wiring requirements?
- Wire should be RVS-2 * 1.0 mm2 or 1.5 mm2.
- How often should the alarm function be tested?
- The alarm function test should be performed every six months.
- What is the purpose of the dust cover?
- The plastic dust cover should be placed after installation or decoration to prevent contamination of the detector.
Send your message to this supplier
People who viewed this also viewed
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$2.50-3.20 / Piece
-
US$62.00-75.00 / Piece
-
US$3.50-5.80 / Piece
-
US$3.80-5.80 / Piece
-
US$2.50-3.60 / Piece
-
US$2.60-3.60 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Addressable Fire Alarm System
- Addressable Heat Detector
- Addressable Heat Detector in Fire Extinguisher for Alarm System
Related Categories
Hot Searches
- Fire Alarm Factories
- Alarm Security Factories
- Fire Alarm System Factories
- Alarm Sensor Factories
- Security Alarm Detector
- Alarm Sensor Detector
- Home Alarm Detector
- Smoke Detector Alarm System
- Alarm Detector Smoke Sensor
- Heat Detector Bulkbuy