Product Highlights

  • Photoelectric Sensor Technology: Insensitive to interfering influences and calibrated to avoid false alarms from cigarette smoke.
  • Long Battery Life: Standard 9V battery provides an average service life of 1 year even during power failures.
  • High-Efficiency Alarm Sound: Generates a loud 85dB warning sound at 3 meters to wake inhabitants during fire emergencies.
  • Automatic Self-Test Function: Advanced electronics ensure operating readiness with a fully automatic test mechanism.
  • Low Battery Warning: Emits a repeated warning sound every 43 seconds for up to one month when power is insufficient.
  • Compact and Easy Installation: Diameter 105mm x 59mm depth with included mounting base for ceiling installation.
  • No Radioactive Substances: Safe design that does not contain any radioactive materials.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel

CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel pictures & photos
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel pictures & photos
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel pictures & photos
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel pictures & photos
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel pictures & photos
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel pictures & photos
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
  • CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
  • CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
    CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
  • CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
    CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
  • CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
    CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
  • CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
    CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
  • CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
    CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
  • CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel
    CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel

Find Similar Products

Product Description

CE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel

 Battery Powered Photoelectric Smoke Alarm with excellent stability and high-sensitivity.

Key Specifications/Special Features

  • Power Source: 9V Battery (included).
  • Audio Alarm: ≥ 85dB/3 meter
  • Temperature Range: 0ºC to 40ºC
  • Humidity Range: 5%-95% relative humidity(RH)
  • Sensor: Photoelectric
  • Size: diameter 105mm in diameter x59mm depth
  • Interconnects: No
  • Easy to install with mounting base included
  • Suitable for any room
  • Low battery signal
  • Test button for simple testing

Photoelectric effect

This recently developed photoelectric sensor-camber is insensitive to interfering influences. Every device is separately calibrated in order to avoid false alarms due to, e.g., cigarette smoke. The power supply is electronically regulated, thereby maintaining a constant sensitivity of the alarm.
 

Battery operation

The functioning of the detector is maintained even in case of a power failure. On an average the battery's (standard 9V battery) service life is 1 year.

Signal lamp (LED)
A flashing small light (every 43s) signalises a failure-free operation.
 

Fully automatic test function

Advanced electronics ensure the best possible operating readiness by means of an automatic self-test function.
 

Battery warning function

By means of a warning sound repeated every 43 seconds (for up to one month), the smoke detector signalises that the power supply of the battery is insufficient and it needs to be replaced.
 

Control button

Temporarily increases the detector's sensitivity to test the alarm function.
 

Noisy (85 dBA) piezoelectric warning sound

Vibrant warning sound in case of fire alarm - high efficiency
 

Approved quality

Thoroughly tested to guarantee highest reliability and a long service life. Produced under rigid quality controls. Certified according to the European norm prEN ISO 12239 for single smoke detectors. CE and TÜV certified security.

This device does not contain any radioactive substances!
 

Function


Smoke caused by fire is very dangerous, especially because of today's widespread use of synthetic materials in modern homes that might generate poisonous vapours when burning.
The DG313 smoke alarm detects smoke caused by smouldering at an early stage and warns by means of a loud, vibrant sound, thereby waking inhabitants up at a point of time when a safe escape is still possible.
The DG313 operates according to the scattered light principle. A light source and a photocell are arranged so as to ensure that normally no light strikes the photocell. The light source is activated in short intervals.
If the concentration of smoke particles in the enclosure reaches a certain level, the light is reflected and reaches the photocell. This will set off a loud fire alarm.
 

Placement

 
  • As most fires in flats start in the living areas, it is recommended to install smoke alarms between the living and sleeping areas.
  • As a minimum requirement a smoke alarm should be installed outside every sleeping area in a flat. If there are separate sleeping areas a smoke alarm is to be installed outside each sleeping area.
  • The minimum requirement for multi-storey houses is to install a smoke alarm on every floor of the house and outside each sleeping area, e.g. in the hallway connecting the sleeping rooms or on the stairway leading to this hallway. If there is a room in the attic, it is strongly recommended to install a smoke alarm on the ceiling as well.
 
  • A smoke alarm shall be installed in the sleeping area of a caravan.
 
  • For complicated or extensive properties please request qualified advice from a safety engineer or the fire brigade.

Information on fire protection is available at your fire brigade helpdesk.

Regarding the installation of single smoke detectors it is distinguished between minimum and increased protection:
CE En14604 Standalone Smoke Detector Smoke Alarm for Home and HotelCE En14604 Standalone Smoke Detector Smoke Alarm for Home and HotelCE En14604 Standalone Smoke Detector Smoke Alarm for Home and HotelCE En14604 Standalone Smoke Detector Smoke Alarm for Home and Hotel

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What type of sensor does this smoke detector use?
It uses a photoelectric sensor based on the scattered light principle, which is insensitive to interfering influences.
How long does the battery last?
The standard 9V battery provides an average service life of 1 year.
Does the alarm make a loud sound?
Yes, it produces a noisy 85dB piezoelectric warning sound at 3 meters to ensure inhabitants are woken up.
Is there a low battery warning?
Yes, a warning sound repeats every 43 seconds for up to one month to signal insufficient power.
Does it have an automatic test function?
Yes, it features a fully automatic test function to ensure the best possible operating readiness.
What are the installation requirements?
It is recommended to install it outside every sleeping area, on every floor of multi-storey houses, and in attic rooms.
Can it be used in a caravan?
Yes, a smoke alarm shall be installed in the sleeping area of a caravan.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now