• En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector
  • En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector
  • En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector
  • En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector
  • En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector
  • En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector

En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector

Type: Smoke Alarm
Usage: Smoke
Installation Mode: Ceiling Mounted
Certification: CE
Application: Home, Communication Electronic Products
Weight: 450g
Samples:
US$ 8.2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
HD106
Color
White
Line
2 Wire
Read Type
Electronic Code
Alarm Type
LED
Transport Package
Carton
Specification
206*95*95MM
Trademark
alarm
Origin
China
HS Code
85319010
Production Capacity
500000/Month

Product Description

Conventional Reflective Beam Detector 

 

1. Overview

 

Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method.  The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in alignment commissioning.

 

The has four adjustable operational ranges of between 8 to 20, 20 to 40, 40 to 70 and 70 to 100 meters beside with three adjustable sensitivity setting ranges from 2.6dB, 3.8dB and 5.8dB to meet the specific environmental requirement. The  works on the principle of reflective infrared beam obscuration. Used in conjunction with a reflector, it will notify the fire alarm panel when the infrared beam is obscured by smoke.

 

The  is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls, leisure centres, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist.

 

2. Main Features

  • EN54-12 Compliance
  • Hassle free alignment,  built with digital guide display and laser beam pointing
  • Employ single-ended design through reflective mirror
  • Four ranges wide monitoring from 8-100 meters via encoder
  • Three users programing sensitivity adjustment
  • Built-in microprocessor
  • Self-diagnosis function can monitor for internal faults
  • Automatic compensation for factors weakening received signals, such as dust contamination, positional movement and ageing of the transmitter
  • Fire and Fault interfacing relays
  • Attractive and pleasing appearance
  • Real User friendly alignment method 

 

3. Technical Specifications

 

 

Standard

   Listed 

LPCB Pending

   Compliance

EN54-12

   Fire Detection and Alarm Systems

BS 5839 Part 1:2002

Specification

   Operating Voltage

20 V to 28 V DC

   Current Parameters 

Standby: 23mA    Commission: 56mA    Alarm: 33mA

   Beam Sensor Sensitivity [via Encoder]                                                        

Level 1: 2.6 dB High Sensitivity

Level 2: 3.8 dB Medium Sensitivity 

Level 3: 5.8 dB Low Sensitivity

   Beam Pathway Length [via Encoder]

 

Span 1: 8 to 20 meters Limited Path

Span 2: 20 to 40 meters Short Path

Span 3: 40 to 70 meters Normal Path

Span 4: 70 to 100 meters Long Path

   Beam Path Angle

±0.5º Directional

   Alignment Guide

Laser Beam Pointer

   Digital Display Guide 

Nixie Tube

   LED Indicator Guide

Red: Fire ; Yellow: Fault ; Green: Alignment

   Reset Time

Less than 2 Second

   Relay Capacity [Fire & Fault]

Normally Open & Close/ 2.0 A; 30 VDC

Physical

   Material / Colour 

ABS / White

   Dimension / Weight

L:190.87 x W:126.87 x H:91.96 mm / 440 gm

   Weight

0.130 Kg with base

Environmental

   Operating Temperature

-10°C to +50°C

   Ingress Protection Rating

IP30 [IP66 glue seal-For permanent fixing]

   Humidity

0 to 95% Relative Humidity, Non condensing

 

 

-----------------------------------------------------------------------------------------------------------------------------------------------------------------------

Dear Friends, Please kindly Note:

1.   Please understand the relationships between the value of Invoice declaration(for custom clearance) and the risk in your country, such as Brazil. Much lower value declaration may cause problem/risk during custom clearance.
2. Please leave a tax number under your order for delivery requirement. 
3. All international expresses delivery are not allowed to send battery, so Batteries are not included in  the independent smoke, the encoder and panel shipments.
4. For the free shipping products  , we will choose one express which is convenient for both of us .If you don't like any specific international express, please feel free to tell us, we will change to another.

We produce a variety of independent sales distribution  smoke detectors , combustible gas detectors, fire alarm systems, security alarm systems products among consumers enjoy a higher status . With many retailers and agents to establish a long-term stable cooperative relations .

Welcome  ODM  OEM.

En54-Lpcb Addressable Ire Alarm System& Conventional Fire Alarm System Use Conventional Reflective Beam Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now