• Smoke Alarm Controller Adressable Input & Output Module
  • Smoke Alarm Controller Adressable Input & Output Module
  • Smoke Alarm Controller Adressable Input & Output Module

Smoke Alarm Controller Adressable Input & Output Module

Type: Smoke Alarm
Usage: Alarm
Installation Mode: Wall Mounted
Application: Home, Communication Electronic Products
Weight: 53G
Color: Rice Yellow
Samples:
US$ 8.2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
M-6607
Line
2 Wire
Read Type
Electronic Code
Temperature
Zero Ten Degree to 50 Degree
Transport Package
Carton
Specification
85*85*36mm
Trademark
module
Origin
China
Production Capacity
50000/Month

Product Description

Instruction manual of M-6007 input and output module

A. Features:

1.Built-in product ID code
2.Using hardware and software filtering technology to improve the module's anti-jamming capability
3.Linkage, 2 bus type, nonpolarity

B. Specifications

1.Working voltage: linkage 15-28V Impulse voltage,DC24V(21V-28V)
2.Working current:
1)Standby current:≤0.65mA
2) action current:≤2.0mA
3.Type:Addressable, 2 wire,nonpolarity;DC24V,nonpolarity
4.Encoding: Electronic code
5.Module's Indication status:
1)Normal monitoring status:The green inspection lights periodically flashed
2)Signal input action indicator: red input action light keep lit
3) start output action instructions: red output action light keep lit, green inspection lights keep lit
6. Operating environment: Temperature-10ºC~55ºC Relative humidity≤95%RH,No condensation
7.Color: beige
8.  Weight: about 72g(with cover)
9.  Dimensions: 65mm×65mm×23mm(without cover)
10. Executive standard:GB 16806-2006

C. Structural features

The dimensions and installation dimensions of the module are shown in Figure 1
Smoke Alarm Controller Adressable Input & Output Module












Figure 1 FW19110 Dimensions and installation dimensions   Figure 2 wiring installation diagram
 

E. Installation


WARNING: Before installing the device, turn off power.
1. Before installation should first check whether the shell is intact, logo is complete.
2. Install the module in the terminal box as shown in Figure 2.
3. Wiring: Figure 3 and Figure 4Smoke Alarm Controller Adressable Input & Output Module


Figure 3: method diagram of high-voltage high-power equipment controlled by M-6007 

Figure 4: FW19110 wiring diagram
Special warning: low-voltage low-power devices directly controlled by the module should meet the following conditions:
  1. Working voltage range:18~30V(recommended 24V)
  2. Working current:≤1.5A
3.Wiring requirements: Wire (bus) should be RVS-2 * 1.0 mm2 or 1.5 mm2;  The DC24Vpower line uses the BV-2 * 1.5 mm2 or 2.5mm2 line; the normally open output line uses the BV-2 * 1.5 mm2 or 2.5mm2 line; RVS-2 * 1.0 mm2 or 1.5mm2 line for the feedback (BUS).

E. Use and operation
Encoding operation: you can use our company's hand-held encoder P-6010  to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242, the address code for the same loop is unique). For details on the steps and methods of encoding, refer to the "P-6010  Handheld Encoder User's Manual".
.

F. Note

1. If the module reported fault after the long-term operation, first check whether the module is damaged, or whether the installation location is changed that not should to be, and then consider other fault of the module.
2. When the controller detects the cleaning forecast, please send the number of smoke detectors back to the company for cleaning, in order to avoid false or false positives, resulting in unnecessary losses.



 