18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory

Product Details
Customization: Available
Type: Fire Alarm Host
Function: Networked
Still deciding? Get samples of US$ 120/Piece
Request Sample
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
7
Year of Establishment
2012-07-20
  • 18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
  • 18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
  • 18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
  • 18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
  • 18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
  • 18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
Find Similar Products

Basic Info.

Model NO.
CP1018
Usage
Fire, Smoke
Certification
CE
Alarm Volume (within 1m)
≥100dB
Networking Mode
Alarm
Receive Frequency
485/232
Wiring Mode
Sub-Line System
Weight
5kg
Color
Gray
Number of Zones
18
Primary AC
90-270VDC
Standby Battery
2*12V
Transport Package
Carton
Specification
325x265x100mm
Trademark
panel
Origin
China
HS Code
8531100000
Production Capacity
500000/Month

Product Description

CONTROL PANEL
The fire panel must be sited internally, in an area
where it is readily accessible by staff on duty and the
fire brigade. The area should be clean and dry and
you should take into account any likelihood of
tampering or vandalism. The ambient light and
sound levels should allow the status of the indicators
to be clearly seen and the internal sounder to be
heard. Full details can be found in BS 5839: Pt1: 1988:
Section 15.3 "Fire Detection and Alarm Systems for
Buildings".

External (key-switch operated):

  • Reset/resound/test zone lamps evacuate
  • Silence alarm sounders
  • Silence fault sounders

Internal:

  • One man detector test
  • Zone isolate
  • Revert to short-circuit: fire (no resistors in call points)

External indicators:

  • Sounder fault
  • Battery/power supply fault
  • Mains on
  • Zone fire
  • Zone fault

Internal indicators:

  • Open circuit zone fault
  • Short circuit zone fault
  • Zone isolated
  • Engineer test selected

Outputs:

  • Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)

Ancillary connections for expansion modules will allow the following:

  • Repeater panels
  • Multiple sounder outputs
  • Connection to landlord panel

18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
 

 Specifications 

18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
18 Zone Conventional Fire Alarm Control Panel Fire Alarm System for Factory
  2 (0.8A supply) 4 / 6 (1.5A supply) 8/10/12/14/16/18
(4.0A supply)
Power specifications   
Mains supply voltage 230±10%V AC, 50/60Hz 230±10%V AC, 50/60Hz 230±10%V AC
50/60Hz
Internal power supply 27V DC 27V DC 27V DC
Total output current limited to 800mA at 240V AC 1500mA at 240V AC 4000mA at 240V AC
Auxiliary power output 27V DC 27V DC 27V DC
Mains supply monitored for failure Yes Yes Yes
Battery charger monitored for failure Yes Yes Yes
Batteries monitored for disconnection and failure Yes Yes Yes
Detector circuit specification
Number of circuits 2 4 or 6 8, 10, 12, 14,16,or 18
Line fault monitored for open circuit Yes Yes Yes
Line fault monitored for short circuit Yes (can be disabled) Yes (can be disabled) Yes (can be disabled)
Line fault monitored for detector removal Yes, if end of line monitor unit fitted in place of end of line resistor
End of line resistor (supplied) value 6.8K Ohm, 5% tolerance, 0.25W 6.8K Ohm, 5% tolerance, 0.25W 6.8K Ohm, 5% tolerance, 0.25W
Detector continuity diodes Silicone 1N4001 or Schottky type (required if end of line monitor unit fitted to give detector removal fault)
Call point resistor value (not supplied) 470 to 680 Ohm, 0.5W 470 to 680 Ohm, 0.5W  470 to 680 Ohm, 0.5W
Maximum number of smoke detectors per zone 20 (maximum detector current = 2mA)   20 (maximum detector current = 2mA)   20 (maximum detector current = 2mA)  
Maximum number of manual  call points per zone No limit No limit No limit
Sounder circuit specifications:
Number of circuits 2 2 2
End of line resistor value 6.8K Ohm, 5% tolerance, 0.25W 6.8K Ohm, 5% tolerance, 0.25W 6.8K Ohm, 5% tolerance, 0.25W
Line fault monitored  for open circuit Yes Yes Yes
Line fault monitored for short circuit Yes Yes Yes
Outputs fused at 1A 1A 1.6A
Maximum total output current all outputs  800mA  1500mA 4000mA
Maximum no of bells at 25mA each bell 32 56 120
Maximum no of electronic sounders at 20mA 40  70  150 
Auxiliary relay contacts  (do not connect mains voltages) 1A 30V DC max  
voltage free
1A 31V DC max  
voltage free
1A 32V DC max  
voltage free
Fuses-all fuses compliant to ice (EN60127 PT2)   
Mains terminal block 200mA/T 20mm 400mA/T 20mm 630mA/T 20mm
Sounder outputs 1A/F 20mm  1A/F 20mm 1.6A/F 20mm
Auxiliary output 1A/F 20mm 1A/F 20mm 1A/F 20mm
Battery fuse 1.6A/F 20mm 1.6A/F 20mm  3A/F 20mm 
Door retaining magnets do not use panel power supply as you will drastically reduce battery standby time
Connection block   
Largest acceptable 2.5mm2 2.5mm2 2.5mm2
Smallest acceptable conductor size 0.75mm2 0.75mm2 0.75mm2 
Dimensions  
Enclosure (width x height x depth) 415 x 265 x 100mm 415 x 265 x 100mm 415 x 265 x 100mm
Weight (without batteries) 5100g 5200g 5500

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier