12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Advanced Optical Sensing: Uses state-of-the-art optical sensing chamber for accurate photo-electronic detection.
  • Wide Voltage Range: Operates on DC 9V to 28V non-polarized power supply for versatile compatibility.
  • Relay Output Capability: Equipped with relay contacts rated at 2A@24V DC for integration with alarm panels.
  • Multiple Certifications: Certified by CE, RoHS, and CCC for safety and compliance in global markets.
  • Compact Design: Weighs only 155g, making it lightweight and easy to install on ceilings or walls.
  • Trouble Condition Alert: LEDs turn off to indicate sensitivity is outside limits or a trouble condition exists.
  • Flexible Mounting: Can be mounted directly onto octagonal, round, or square junction boxes without adapters.

Product Images of 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output

12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output pictures & photos
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output pictures & photos
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output pictures & photos
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output pictures & photos
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output pictures & photos
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output pictures & photos
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
  • 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
  • 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
    12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
  • 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
    12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
  • 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
    12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
  • 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
    12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
  • 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
    12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
  • 12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
    12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output

Find Similar Products

Product Description


The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel. 
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. 
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.
 
2. SPECIFICATIONS
Operating Voltage Range:         9 to 28 VDC Volts Non-polarized
Standby Current:               ≤200µA
Maximum Alarm Current (LED on):   ≤45mA 
Alarm Relay Contact Ratings:       2A@ 24V DC
Operating Humidity Range: ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range:  -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity:          1.06±.26%FT
 
WARNING
TO PREVENT DETECTOR CONTAMINATION AND SUBSEQUENT WARRANTY CANCELLATION, THE SMOKE DETECTOR MUST REMAIN COVERED UNTIL THE AREA IS CLEAN AND DUST FREE.
 
3. INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
 
INSTALL THE DETECTOR BASE
1. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in accordance with the fire standard in your country.
2. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto an electrical junction box such as an octagonal (75mm, 90mm or 100mm), a round (75mm), or a square (100mm) box without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the wires on the terminals, 
12V/42V 4 Wirw Photoelectric Smoke Detector  with Relay Output
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the operating voltage range?
The detector operates on a non-polarized DC voltage range of 9 to 28 VDC.
How does the LED indicator work?
Two LEDs flash every six seconds to show power is on. They latch on during an alarm and turn off if a trouble condition exists.
Can the alarm be reset remotely?
No, the alarm can only be reset by a momentary power interruption.
What are the installation requirements?
Install on a ceiling or wall according to local fire standards. Wires must conform to local codes and regulations.
Is the detector sensitive to dust?
Yes, the detector must remain covered until the area is clean and dust-free to prevent contamination and warranty cancellation.
What certifications does the product have?
The product holds CE, RoHS, and CCC certifications.
How is the alarm relay rated?
The alarm relay contact rating is 2A at 24V DC.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now