• Optical Chamber 4-Wire Smoke Detector with Relay Output
  • Optical Chamber 4-Wire Smoke Detector with Relay Output
  • Optical Chamber 4-Wire Smoke Detector with Relay Output
  • Optical Chamber 4-Wire Smoke Detector with Relay Output
  • Optical Chamber 4-Wire Smoke Detector with Relay Output
  • Optical Chamber 4-Wire Smoke Detector with Relay Output

Optical Chamber 4-Wire Smoke Detector with Relay Output

Type: Smoke Alarm
Installation Mode: Ceiling Mounted
Certification: CE, RoHS, CCC
Application: Home, Communication Electronic Products
Weigt: 155g
Alarm Type: Sound Light
Samples:
US$ 9.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
PZ-05
Color
White
Power
DC9V-28V
Degree
Zreo Ten Degree to 50 Degree
Transport Package
Catton
Specification
103*103*55mm
Trademark
alarm
Origin
China
Production Capacity
100000/Month

Product Description


The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel. 
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. 
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
Heat detector and smoke & heat detector combine a photo electronic sensing chamber and a temperature heat detector.
 
2. SPECIFICATIONS
Operating Voltage Range:         9 to 28 VDC Volts Non-polarized
Standby Current:               ≤200µA
Maximum Alarm Current (LED on):   ≤45mA 
Alarm Relay Contact Ratings:       2A@ 24V DC
Operating Humidity Range: ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range:  -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity:          1.06±.26%FT
 
WARNING
TO PREVENT DETECTOR CONTAMINATION AND SUBSEQUENT WARRANTY CANCELLATION, THE SMOKE DETECTOR MUST REMAIN COVERED UNTIL THE AREA IS CLEAN AND DUST FREE.
 
3. INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
 
INSTALL THE DETECTOR BASE
1. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in accordance with the fire standard in your country.
2. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto an electrical junction box such as an octagonal (75mm, 90mm or 100mm), a round (75mm), or a square (100mm) box without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the wires on the terminals, 