High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High Sensitivity Detection: Uses highly sensitive thermal elements to improve response speed of temperature sensor.
  • Advanced Anti-Interference: Hardware and software filtering technology improves anti-interference ability.
  • Flexible Electronic Coding: Advanced electronic code technology allows unique address coding from 1 to 242.
  • 2-Wire Nonpolarity System: Supports 2-bus linkage type with nonpolarity wiring requirements.
  • Clear Status Indication: LED blinks for normal, stays lit for fire, and off/irregular for failure status.
  • CE Certified Product: Meets CE certification standards and GB 4716-2005 executive standard.
  • Compact and Lightweight: Weighs only 120g with white color and 15-28V operating voltage.

Product Images of High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm

High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm pictures & photos
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm pictures & photos
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm pictures & photos
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm pictures & photos
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm pictures & photos
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm pictures & photos
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
  • High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
    High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
  • High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
    High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
  • High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
    High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
  • High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
    High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
  • High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
    High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
  • High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
    High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm

Find Similar Products

Product Description

Instruction manual of H-6002 heat detector  

A. Features

1.Built-in product ID code
2.Using hardware and software filtering to improve the anti-interference ability of the temperature detector
3.2 bus, linkage type,nonpolarity
4.Advanced electronic code technology improves the flexibility of coding
5. Using highly sensitive thermal elements to improve the response speed of temperature sensor.

B. Specifications

1.Working voltage: 15-28V Impulse voltage
2.Working current:
1)Standby current: ≤0.5mA
2)Alarm current: ≤3.0mA
3.Type:2 bus(nonpolarity)
4.Encoding: Electronic code
5.Temperature detector's status indication:
1)Normal monitoring status: LED light will blink periodically
2)Fire status: remain lit
3)Failure status: LED light remain off or blink irregularly
6.Operating environment:Temperature-10ºC~50ºC, Relative humidity≤90%RH no condensation
7.Color: white
8.Weight:120g
9. Executive standard:GB 4716-2005

C. Outline diagram

(Figure 1)


Figure 1:H-6002 Dimensions  

High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm


 

D. Installation

1.Installation method
Figure 2 shows the installation of the temperature detector


   
Figure 2 H-6002 installation diagram
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm

86H50 standard embedded box can be used as pre-embedded box; when installation, locate heat detector on the base and rotate clockwise.

2. Wiring requirements: Wire should be RVS-2 * 1.0 mm2 or 1.5 mm2
3. WARNING: Before installing the heat detector, turn off the power and make sure that all the bases are installed securely.

E. Use and operation
Encoding operation: you can use our company's hand-held encoder p6010 to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242, the address code for the same loop is unique). Press the "write code" button, if encoding is successful, the encoder will display the address number after sending the address code. If failed, the encoder will display "FAL" after sending the address code.
For details on the steps and methods of encoding, refer to the P6010  Handheld Encoder User's Manual".
.

F. Note

1. The plastic part attached with heat detector is dust cover. Please cover the dust cover after the installation or room decoration, painting construction, so that the smoke detectors are contaminated.
2. The alarm function test of smoke detector should be performed every six months.
3. When the controller detects the cleaning forecast, please send the number of smoke detectors back to the company for cleaning, in order to avoid false or false positives, resulting in unnecessary losses.

High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
High Sensitivity Addressable Heat Detector 100% Full Inspection for Fire Alarm
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the operating voltage range?
The working voltage is 15-28V with impulse voltage capability.
How many addresses can be supported?
The address code range is 1-242, and each code must be unique within the same loop.
What is the standby current consumption?
The standby current is less than or equal to 0.5mA.
How do I encode the device?
Use the P6010 handheld encoder to connect to the terminals and write the unique address code.
What is the recommended wiring type?
Wire should be RVS-2 * 1.0 mm2 or 1.5 mm2.
How often should the alarm function be tested?
The alarm function test should be performed every six months.