Product Highlights

  • Four Style B Initiating Device Circuits: Supports two-wire smoke detectors and normally-open contact devices across all zones.
  • Built-in Fire Fighting Output: Provides 2 AMP@28VDC extinguishant release output for automated fire suppression.
  • Programmable One-Man Walk-Test: Allows silent or audible testing with single-person operation capability.
  • Per IDC Disable/Enable Control: Enables independent control of each Initiating Device Circuit for flexibility.
  • Reverse Polarity Protection: Ensures system safety and prevents damage from incorrect wiring connections.
  • Wide AC Voltage Range: Operates on 90-270 AC 50/60 Hz for global compatibility.
  • Compact and Lightweight Design: Weighs only 4kg, making it easy to install and transport.

Product Images of Automatic Extinguisher Fire Control Panel for Fire Fighting System

Automatic Extinguisher Fire Control Panel for Fire Fighting System pictures & photos
Automatic Extinguisher Fire Control Panel for Fire Fighting System
Automatic Extinguisher Fire Control Panel for Fire Fighting System pictures & photos
Automatic Extinguisher Fire Control Panel for Fire Fighting System
Automatic Extinguisher Fire Control Panel for Fire Fighting System pictures & photos
Automatic Extinguisher Fire Control Panel for Fire Fighting System
Automatic Extinguisher Fire Control Panel for Fire Fighting System pictures & photos
Automatic Extinguisher Fire Control Panel for Fire Fighting System
Automatic Extinguisher Fire Control Panel for Fire Fighting System pictures & photos
Automatic Extinguisher Fire Control Panel for Fire Fighting System
Automatic Extinguisher Fire Control Panel for Fire Fighting System pictures & photos
Automatic Extinguisher Fire Control Panel for Fire Fighting System
  • Automatic Extinguisher Fire Control Panel for Fire Fighting System
    Automatic Extinguisher Fire Control Panel for Fire Fighting System
  • Automatic Extinguisher Fire Control Panel for Fire Fighting System
    Automatic Extinguisher Fire Control Panel for Fire Fighting System
  • Automatic Extinguisher Fire Control Panel for Fire Fighting System
    Automatic Extinguisher Fire Control Panel for Fire Fighting System
  • Automatic Extinguisher Fire Control Panel for Fire Fighting System
    Automatic Extinguisher Fire Control Panel for Fire Fighting System
  • Automatic Extinguisher Fire Control Panel for Fire Fighting System
    Automatic Extinguisher Fire Control Panel for Fire Fighting System
  • Automatic Extinguisher Fire Control Panel for Fire Fighting System
    Automatic Extinguisher Fire Control Panel for Fire Fighting System

Find Similar Products

Product Description

Conventional Fire Fighting Panel

Key Specifications/Special Features

  • Four Style B (Class B) Initiating Device Circuits (IDCs).
  • All zones accept two-wire smoke detectors and any normally-open contact devices.
  • One built-in Fire Fighting Ouput.
  • 24-volt operation.
  • Resettable four-wire smoke detector power @ 500 mA.
  • Non-resettable power @ 500 mA.
  • One-man walk-test programmable for silent or audible test.
  • Disable/Enable control per IDC.
  • Reverse polarity protection.
    Automatic Extinguisher Fire Control Panel for Fire Fighting System
    Automatic Extinguisher Fire Control Panel for Fire Fighting System
     

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the alarm volume level?
The alarm volume is at least 100dB within a 1-meter range.
How many initiating device circuits are supported?
The panel supports four Style B (Class B) Initiating Device Circuits.
What type of detectors can be connected?
All zones accept two-wire smoke detectors and any normally-open contact devices.
What is the extinguishant release output capacity?
The output capacity is 2 AMP@28VDC.
Is the panel programmable for testing?
Yes, it features a one-man walk-test programmable for silent or audible tests.
What is the operating voltage?
The system operates on 24 volts with a primary AC range of 90-270 AC 50/60 Hz.
Does the panel offer reverse polarity protection?
Yes, it includes reverse polarity protection to ensure safe operation.
What are the payment terms accepted?
Accepted payment terms include LC, T/T, D/P, PayPal, Western Union, and small-amount payments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now