Secured Trading Service

Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High EMI Immunity: Ensures stable operation in environments with high electromagnetic interference.
  • Dual Sounder Circuits: Supports two independent sounder circuits with optional alarm relay connections.
  • Expandable System: Allows connections to repeater panels, multiple sounder outputs, and landlord panels.
  • Comprehensive Testing: Features dedicated tests for power supply, sounder monitoring, and detector circuits.
  • Key Switch Control: Enables secure arm control mode to activate push buttons and manage system status.
  • Wide Input Voltage: Accepts AC 100-240V, 50/60Hz for versatile global power compatibility.
  • Clear Visual Indicators: Green and yellow LEDs display mains, battery, and fault statuses clearly.
  • Durable Iron Construction: Built with iron material for robustness and long-term reliability.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System

Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System pictures & photos
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System pictures & photos
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System pictures & photos
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System pictures & photos
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System pictures & photos
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System pictures & photos
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
  • Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
  • Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
    Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
  • Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
    Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
  • Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
    Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
  • Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
    Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
  • Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
    Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
  • Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
    Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System

Find Similar Products

Product Description

EXTERNAL (KEYSWITCH OPERATED) 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders

Product Description

 

TESTING THE PANEL
When testing the panel with the panel lid open, always isolate the Mains and disconnect the batteries. The panel can be tested before
connecting field wiring. If testing before installation, ensure that the end-of-line resistors are fitted in the panel's sounder and detector
terminal blocks.
Position and connect two suitable batteries in the panel as show Fig3&4. When the batteries are connected, the BATTERY SUPPLY
indicator will light in green. When a low voltage fault occurs in the battery, the BATTERY SUPPLY indicator will light in yellow and
the warning beeper will sound.
Connect the Mains supply wiring and turn the Mains supply on. The MAINS SUPPLY indicator will light in green. When the mains
power is cut off, the MAINS SUPPLY indicator will light in yellow and the warning beeper will sound.
KEY SWITCH
The panel is normal. If the push buttons are inoperative.
TURN THE KEY SWITCH TO ARM CONTROLS POSITION, the button is now valid.
Note: None of the panel's push buttons are operative unless the key switch is in the ARM CONTROLs position.
TEST INDICTOR AND BUZZER
Press RESET/TEST, all indicators will light after 3 seconds, the warning buzzer will sound, and the panel will return to normal l after 5
seconds.
TEST THE POWER SUPPLY MONITORING CIRCUIT
Switch off the Mains, the MAINS SUPPLY yellow indicator will light and the warning beeper will sound. Press SILENCE
the warning beeper will silence but the MAINS SUPPLY yellow light will remain lit.Reconnect the mains supply and after
a short time the panel will revert to normal and the MAINS SUPPLY green indicator will light.
Disconnect the battery. The BATTERY SUPPLY yellow indicator will light and the warning beeper will sound.
Reconnect the battery and after a short time the panel will revert to normal and the BATTER SUPPLY green indicator
will light.
Note: This test should be carried out with a set of new and fully charged batteries-deteriorated cells will show a fault
even when connected and charged up.
TEST THE SOUNDER MONITORING CIRCUITS
DO NOT carry out this test with the ZONE FIRE indicator lit as sounder fuses limit could blow. Ensure that the end-of
line resistor is connected across each of the sounder circuits on terminals S1+&S1-, S2+&S2-.
Open circuit the sounder terminals S1+&S1- or S2+&S2- by disconnecting one leg of the end-of-line resistor.The
ALARM SOUNDER yellow indicator will light and the warning beeper will sound. Press the SILENCE the warning
beeper will silence but the ALARM SOUNDER fault yellow indicator will remain lit. Remake the circuit and the panel will
revert to normal.
TEST THE DETECTOR MONITORING CIRCUIT
Make sure an end-of-line device (EOLD) is connected across the zone circuit terminals. The EOLD would either be a
Resistor or Electronic Monitoring unit (EMU) and associated panel Module depending on the installation. Refer to Fig6
instruction for connections.
Use the keys witch to turn off the alarm sound in two ways
1 .Press the SILENCE key once to turn off the panel buzzer sound.
2 . Hold down the SILENCE key for more than 5 seconds to turn off the panel buzzer and alarm sound



INTERNAL 

• One Man Detector Test 

• Zone isolate 

• Revert to short circuit = fire (no resistors in call points)

 

EXTERNAL INDICATORS 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders
 

INTERNAL INDICATORS 

• Open circuit zone fault 

• Short circuit zone fault 

• Zone isolate 

• Engineer test selected

 

Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
 


OUTPUTS

Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)

Ancillary connections for expansion modules will allow the following:

1.Repeater panels

2.Multiple sounder outputs

3.Connection to landlord panel
 

Input Voltage AC 100-240V, 50/60Hz
Internal Power Supply DC 30V 3A
Total Output Current ≤200mA @ 220V
Chipset 32-bit Micro processor
Zone 1-8 Zone(s)
Max Number of Smoke Detector per Zone 20-25 pcs
 
Capacity High EMI Immunity
Backup Battery DC 12V/2.2AH * 2 (not include)
Dimension 325x265x100mm
Operating Temperature 0ºC ~ +50ºC
Weight(Without battery) 2700g
Material  Iron
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
Conventional Fire Alarm Control Panel for Fire Alarm System and Security Alarm System
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the maximum number of smoke detectors per zone?
Each zone can support a maximum of 20 to 25 smoke detectors.
What are the dimensions of the panel?
The panel dimensions are 325x265x100mm.
Does the panel include backup batteries?
No, the panel requires two DC 12V/2.2AH batteries which are not included.
How do I silence the alarm sounder?
You can silence the alarm by pressing the SILENCE key once for the buzzer or holding it for over 5 seconds to silence both the buzzer and alarm sound.
Can the system be expanded?
Yes, ancillary connections allow for expansion modules, repeater panels, and multiple sounder outputs.
What is the lead time for orders?
Lead time is within 15 workdays during the off-season and one month during the peak season.
What payment methods are accepted?
Accepted payment terms include LC, T/T, D/P, PayPal, Western Union, and small-amount payments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now