Contributing to The Extinguishant Release Decision for Gas Extinguishing System

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • EN54 & EN12094 Certified: Complies with European standards EN54-2, EN54-4, and EN12094-1 for safety and reliability.
  • 4-Zone Detection Capability: Features four Style B initiating device circuits supporting smoke detectors and contact devices.
  • Gas Extinguishant Control: Integrated control for gas extinguishing systems with up to 75-second delay and flooding time control.
  • Flexible Alarm Modes: Supports silent/audible tests, manual-only mode, and distinct pre-discharge/released warning signals.
  • Comprehensive Relay Outputs: Includes fire, local fire, first/second stage, and extract fan contacts for external equipment triggering.
  • Robust Power System: 24V operation with integral battery charger, supporting two 12V sealed lead-acid batteries for backup.
  • Safety & Monitoring Features: Features reverse polarity protection, low pressure switch input, and emergency hold device for safety.
  • Professional Installation Support: Designed for indoor use with clear guidelines for trained personnel installation per IEE regulations.

Product Images of Contributing to The Extinguishant Release Decision for Gas Extinguishing System

Contributing to The Extinguishant Release Decision for Gas Extinguishing System pictures & photos
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System pictures & photos
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System pictures & photos
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System pictures & photos
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System pictures & photos
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System pictures & photos
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
  • Contributing to The Extinguishant Release Decision for Gas Extinguishing System
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System
  • Contributing to The Extinguishant Release Decision for Gas Extinguishing System
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System
  • Contributing to The Extinguishant Release Decision for Gas Extinguishing System
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System
  • Contributing to The Extinguishant Release Decision for Gas Extinguishing System
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System
  • Contributing to The Extinguishant Release Decision for Gas Extinguishing System
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System
  • Contributing to The Extinguishant Release Decision for Gas Extinguishing System
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System

Find Similar Products

Product Description

CM1004 Extinguishant Fire Alarm Control Panel

1. Key Specifications/Special Features

  • Four Style B (Class B) Initiating Device Circuits (IDCs).
  • All zones accept two-wire smoke detectors and any normally-open contact devices.
  • One built-in Fire Fighting Ouput.
  • 24-volt operation.
  • Resettable four-wire smoke detector power @ 500 mA.
  • Non-resettable power @ 500 mA.
  • One-man walk-test programmable for silent or audible test.
  • Disable/Enable control per IDC.
  • Reverse polarity protection.
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System
    Contributing to The Extinguishant Release Decision for Gas Extinguishing System
     

2. Outview
The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing system and has four detection zones, any or all of which are capable of contributing to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.

In addition to the requirements of EN54-2 the control panel has the following facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes. EN54-2 Section 10 option with requirements

Delay of the actioning of fire alarm devices (sounders) so that an alarm may be verified before a premises is evacuated. EN54-2 Section 7.11 option with requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises upon the detection of a fire condition or the operation of a manual call point.  EN54-2 Section 7.8 option with requirements

In addition to the requirements of EN54-2, all control panels have voltage free relay contacts for fire and local fire which operate upon a fire condition. These are to be used for local control and signaling.

In addition to the requirements of EN12094-1 the control panel has the following facilities:
Delay of extinguishing signal of up to 75 seconds. EN12094-1 Section 4.17 option with requirements.

Signal representing the flow of extinguishing agent to indicate the released condition. EN12094-1 Section 4.18 option with requirements.

Monitoring of the status of components by way of a low pressure switch input.  EN12094-1 Section 4.19 option with requirements.
Emergency hold device to enable the extinguishant delay time to be extended. EN12094-1 Section 4.20 option with requirements.

Control of flooding time to deactivate the releasing output after a set period of time. EN12094-1 Section 4.21 option with requirements.

Manual only mode to disable the release of extinguishant via automatic detection devices. EN12094-1 Section 4.23 option with requirements.

Triggering of equipment outside the system by way of first and second stage contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements

Activation of alarm devices with different signals to indicate pre-discharge and released warnings using different sounds. EN12094-1 Section 4.30 option with requirements.

3. Safety
Suppliers of articles for use at work are required under section 6 of the Health and Safety at Work act 1974 to ensure as reasonably as is practical that the article will be safe and without risk to health when properly used.
An article is not regarded as properly used if it is used 'without regard to any relevant information or advice' relating to its use made available by the supplier.
This product should be installed, commissioned and maintained by trained service personnel in accordance with the following:

(i) IEE regulations for electrical equipment in buildings
(ii) Codes of practice
(iii) Statutory requirements
(iv) Any instructions specifically advised by the manufacturer

According to the provisions of the Act you are therefore requested to take such steps as are necessary to ensure that you make any appropriate information about this product available to anyone concerned with its use.
This equipment is designed to operate from 230V/50Hz mains supplies and is of class 1 construction.  As such it must be connected to a protective earthing conductor in the fixed wiring of the installation and a readily accessible double pole disconnect device meeting the requirements of EN60950/IEC950 which disconnects live and neutral simultaneously shall  be incorporated in the fixed wiring.
Switch disconnect devices such as MK Sentry 63A or similar are suitable for this.
Failure to ensure that all conductive accessible parts of this equipment are adequately bonded to the protective earth will render the equipment unsafe.
This control panel is environmental class A and is designed for indoor use only at temperatures between -50ºC(+/- 3) and +400ºC (+/- 2) and with a maximum relative humidity of 95%.
The IP rating for the enclosure is IP30.
Operation outside of these limits may render the equipment unsafe.
 
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
 
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System

Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
Contributing to The Extinguishant Release Decision for Gas Extinguishing System
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What certifications does the CM1004 panel hold?
The CM1004 is designed in accordance with European standards EN54-2, EN54-4, and EN12094-1 for fire detection and gas extinguishing systems.
How many detection zones are available?
The panel features four Style B (Class B) Initiating Device Circuits (IDCs), allowing any or all zones to contribute to the extinguishant release decision.
Can the panel control gas extinguishing systems?
Yes, it includes a built-in Fire Fighting Output and facilities for delaying extinguishing signals up to 75 seconds, monitoring component status, and controlling flooding time.
What types of detectors are supported?
All zones accept two-wire smoke detectors and any normally-open contact devices, with resettable and non-resettable power options available.
What are the power supply requirements?
The panel operates on 24V with an integral mains-powered battery charger, supporting two 12V sealed lead-acid batteries in series for backup power.
Is manual override available for extinguishant release?
Yes, the panel includes a manual-only mode to disable automatic release via detection devices and an emergency hold device to extend the delay time.
What safety precautions are required for installation?
Installation must be performed by trained personnel in accordance with IEE regulations and statutory requirements, ensuring proper earthing and disconnect devices.