Product Highlights

  • High Device Capacity: Supports one loop with a maximum of 240 devices for scalable fire alarm systems.
  • Advanced LCD Display: Features a 128x64 lattice graphic LCD screen for clear alarm and fault information.
  • Built-in Printing Function: Equipped with an internal printer to output fire alarm and operation records.
  • Flexible Power Supply: Operates on 220VAC with a 2x12V/12AH standby battery backup system.
  • Wall-Mounted Design: Compact structure designed for easy wall installation in various buildings.
  • Multi-Mode Output Control: Supports active and passive modes for sounder strobe and routing devices via jumpers.
  • Wide Operating Temperature: Functions reliably in temperatures ranging from 0 to 40 degrees Celsius.
  • Reliable Communication Bus: Utilizes non-polarity two-wire bus terminal for stable device connectivity.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System

All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System pictures & photos
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System pictures & photos
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System pictures & photos
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System pictures & photos
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System pictures & photos
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System pictures & photos
All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
  • All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
  • All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
    All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
  • All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
    All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
  • All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
    All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
  • All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
    All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
  • All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
    All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
  • All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System
    All of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System

Find Similar Products

Product Description

Installation and Operation Manual

FW6000 Fire Alarm Control Panel


FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed by our company for applications in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices.

Note: COM port needs grounding
1,(Monitoring Start Output)HJ: Active NO terminal to Fire alarm routing device (use jumper to switch  
between passive and active), which will close to connect +24V output after started (each points with a
max output current of 100mA)
2,(Monitoring Start Output)SG: Active NO terminal to Sounder Strobe (Both active and passive modes,  
use jumper to switch between passive and active), which will close to connect +24V output after
started (with max output current of 100mA for each direct-start point)
3,BUS: Non-polarity two-wire bus terminal
4,Linkage power supply output: 24VDC(Max output current 1A)
5,Main board power supply input: 220VAC
6,Grounding Terminal: GroundingAll of Buildings and Hotel Addressable Fire Alarm Control Panel and Fire Alarm System

2.4 Technical Specifications
2.4.1 Power Supply:
AC power: Nominal operation voltage 220VAC (187VAC ~ 242VAC)
Standby Battery: 2 x 12V/12AH
2.4.2 Operating Environment:
Temperature: 0ºC~+40ºC
Relative Humidity: ≤95%, non-condensing
2.4.3 Capacity: One loop with maximum 240 devices
2.4.4 Display: LCD 128×64 lattice graphic
2.4.5 Dimension: (Length ×Width ×Height):330.0mm×130.0mm×400.0mm
2.4.6 Wiring requirement
1,Recommend to use RVS2×1.0MM2 or RVS2×1.5MM twisted wire for CAN communication wire and bus   
wire, while use RVSP2×1.0mm2 at the high interference environment.
2,Not allowed to lay CAN communication wire and telephone line together with bus wire inside the same        
   multi-core cable.

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the maximum device capacity?
The FW6000 panel supports one loop with a maximum of 240 devices.
What is the display type?
It features an LCD 128x64 lattice graphic display for monitoring alarms and faults.
Does the panel have a built-in printer?
Yes, it is equipped with a built-in printer to print out alarm and operation information.
What is the power supply requirement?
It requires 220VAC nominal voltage and includes a 2x12V/12AH standby battery.
What is the operating temperature range?
The system operates within a temperature range of 0 to 40 degrees Celsius.
Can the output modes be switched?
Yes, jumpers allow switching between active and passive modes for sounder strobe and routing devices.
What is the installation method?
The panel is designed as a wall-mounted type for flexible configuration.
What are the wiring requirements?
Use RVS2x1.0MM2 or RVS2x1.5MM twisted wire for communication, avoiding mixing with telephone lines in the same cable.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now