• Security Alarm System Addressable Sound Fire Strobe Siren
  • Security Alarm System Addressable Sound Fire Strobe Siren
  • Security Alarm System Addressable Sound Fire Strobe Siren

Security Alarm System Addressable Sound Fire Strobe Siren

Type: Smoke Alarm
Usage: Sound
Installation Mode: Wall Mounted
Application: Home, Communication Electronic Products
Weight: 150g
Color: Red
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
SG6008
Material
ABS+PC
Voltage
24V
Power Voltage
DC24V
Transport Package
Carton
Specification
145*115*60mm
Trademark
fire
Origin
China
Production Capacity
500000/Month

Product Description

Installation instructions of SG-6008 fire alarm sounder

  1. Features:
  1. It features as eye-catching, long life and low power consumption with ultra-bright white LED light.
  2. Electronic encoding. It can be addressed directly by the electronic coder, which makes the project debugging simple and reliable
  3. Integrated structural design, reliable contact, easy construction.
  1. Technical feature
  1. Working voltage:
 linkage voltage:24V       allowable range:15V~28V(Vp-p)
power voltage:DC24V      allowable range:DC20V~DC28V
  1. Working current:
 linkage monitoring current≤0.6mA        linkage start current≤5mA
power monitoring current≤2mA       power start current≤50mA
3. Sound pressure level:75~115dB(A-weighted)
4.Tone cycle:4×(1±20%)s
5. Flash frequency:2×(1±20%)Hz
6.Encoding: electronic encoding,occupy a linkage coding point, encoding range can be set between 1 ~ 242
7.Type: connect with the addressable fire alarm or 24V 2 bus of controller
8.Operating environment:
temperature:-10ºC~+50ºC
Relative humidity95%,No condensation
9. Dimensions : 145mm×115mm×60mm
10.Shell material and color: ABS+PC,red
11.Weight:about 150g(with base)
12.Executive standard:GA 385-2002

C. Structural features and working principle 

Figure 1 shows the outline of fire alarm sounder

Figure 1 Installation diagramSecurity Alarm System Addressable Sound Fire Strobe Siren
 

D.Installation

WARNING: 1. Before installing the equipment, please disconnect the power of the circuit and make sure that the bottom case is securely installed.
2. Installation location should keep away from rain and moisture and avoid direct sunlight.
    
1. Before installation should first check whether the shell is intact, logo is complete.
2. Figure 2 shows the terminals of fire alarm sounder. The wiring instructions are as follows:
24V + / 24V-: DC24Vpower input terminal (nonpolarity).
Z1, Z2: bus input, nonpolarity
S: passive switch trigger signal input (the fire alarm sounder will be triggered when 

 
Figure 2 terminal and base diagram          Figure 3 installation diagramSecurity Alarm System Addressable Sound Fire Strobe Siren

3.Application method of fire alarm sounder in fire alarm systems shows in Figure 4

Figure 4 Security Alarm System Addressable Sound Fire Strobe Siren
Schematic diagram of the system connection

E. Operation

Encoding operation: you can use our company's hand-held encoder SG-6008 to live coding. When encoding, connect the two clips of the encoder to the two terminals of the linkage, open the handheld encoder power, enter the address code to be written (address code range must be: 1-242). Press the "write code" button.
For details on the steps and methods of encoding, refer to the "SG-6008 Handheld Encoder User's Manual".
F. Note
The function test of fire alarm sounder should be performed every six months after putting into operation.



 