2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Ultra Low Power Consumption: Features non-polarized two-wire bus with max monitoring current of 0.2mA.
  • High False Alarm Immunity: Combined infrared and blue ray detection technology reduces false alarms.
  • No-Clean Design: Patented labyrinth and new chamber design minimize dust and light interference.
  • 360-Degree Visual Indication: Top-mounted LED provides clear status indication from any angle.
  • Wide Operating Voltage: Supports DC6V to 27V for flexible power supply compatibility.
  • Long Loop Distance: Maximum loop length up to 5km using ZR-RVS-2*1.5mm2 twisted pair.
  • Unique Addressable ID: Each detector has a unique ID (1-200) for easy online modification.
  • Drift Compensation: Adjusts for environmental changes and aging to extend device lifespan.

Product Images of 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System

2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System pictures & photos
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System pictures & photos
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System pictures & photos
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System pictures & photos
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System pictures & photos
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System pictures & photos
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
  • 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
  • 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
    2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
  • 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
    2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
  • 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
    2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
  • 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
    2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
  • 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
    2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
  • 2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
    2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System

Find Similar Products

Product Description

Photoelectric Smoke Detector
Features
  • Ultra low power consumption with non-polarized two wire bus.
  • Professional microchip provides highest reliability.
  • Combined infrared ray with blue ray detection technology allows a higher level of false alarm immunity.
  • Drift compensation for environmental changes and device aging, reduces sensitivity changes and extends the lifespan.
  • Patented labyrinth design, smoke enters from the top of the detector to remove azimuth error.
  • A completely new chamber design is proven in extensive testing to be more efficient, less liable to false alarm due to strong light, strong interference and dust and achieve no-clean basically.
  • The indicator LED is on the top of the detector that provide 360 ° local visual indication of the device status.
  • Each detector has a unique detector ID at the back.
  • Electrically addressed, can be modified online or by a programmer.
  • Rotary designed to ease installation.
Technical Specifications

Installation
  • Fix the base on the embedded junction box or the mounting location with M4 screws.
  • Adopt ZR-RVS-2*1.5mm2 twisted pair to respectively run through the entrance holes in the base and polarity-indiscriminately connect to the S+ and S- terminals.
  • Set address (1 to 200) on the detector by programmer.
  • Install the detector on the base.
Operating Voltage Range DC6V to 27V
Monitoring Current(Max) 0.2mA
Operating Current(Max) 0.35mA
LED indicator Red. Flashing - Monitoring; Steady - Alarm.
Maximum loop length 5km (based on ZR-RVS-2*1.5mm2)
Temperature Range -10 °C-+55 °C
Humidity
Sensor Base
Wind speed(Max)
<95% rel. (non-condensing)
J-SCM08
5m/s
Protection area 60m2
Protection Category IP30
Dimensions( XH) 100.0x46.0mm (including the base)
Wiring method two-wire bus (non-polarized)
Standard GB 4715-2005
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
2 Wire 24V DC Fire Alarm Addressable Smoke Detector for Alarm System
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the operating voltage range?
The detector operates within a DC voltage range of 6V to 27V.
How is the address set on the detector?
The address (1 to 200) is set on the detector using a programmer.
What is the maximum loop length?
The maximum loop length is 5km based on ZR-RVS-2*1.5mm2 wiring.
Does the detector require regular cleaning?
No, the patented design achieves a no-clean status by resisting dust and interference.
How is the device installed?
Fix the base with M4 screws and install the detector on the base.
What does the LED indicator show?
Flashing red indicates monitoring status, while steady red indicates an alarm.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now