Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel

Shenzhen Puzhesi Technology Co., Ltd.
  • Audited Supplier
  • 9 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Networked Fire Alarm System: Supports networking mode for alarm signals and connects to repeater panels or landlord panels.
  • Expandable Zone Capacity: Supports 2 to 8 zones with up to 20-25 smoke detectors per zone for flexible installation.
  • Robust EMI Immunity: Features high EMI immunity with a 32-bit microprocessor for stable operation in complex environments.
  • Comprehensive Control Functions: Includes external keyswitch controls for reset, test, evacuate, and silence functions for both alarms and faults.
  • Wide Input Voltage Range: Accepts AC 100-240V, 50/60Hz input, ensuring compatibility with various power supply standards.
  • Durable Iron Construction: Built with iron material for durability, measuring 325x265x100mm and weighing 2700g without battery.
  • Flexible Output Options: Provides two sounder circuits and ancillary connections for expansion modules and multiple outputs.

Product Images of Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel

Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel pictures & photos
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel pictures & photos
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel pictures & photos
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel pictures & photos
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel pictures & photos
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel pictures & photos
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
  • Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
  • Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
    Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
  • Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
    Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
  • Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
    Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
  • Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
    Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
  • Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
    Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
  • Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
    Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel

Find Similar Products

Product Description

EXTERNAL (KEYSWITCH OPERATED) 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders

INTERNAL 

• One Man Detector Test 

• Zone isolate 

• Revert to short circuit = fire (no resistors in call points)

 

EXTERNAL INDICATORS 

• Reset / Resound / Test Zone Lamps 

• Evacuate 

• Silence Alarm Sounders 

• Silence Fault Sounders
 

INTERNAL INDICATORS 

• Open circuit zone fault 

• Short circuit zone fault 

• Zone isolate 

• Engineer test selected

 

Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
 


OUTPUTS

Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)

Ancillary connections for expansion modules will allow the following:

1.Repeater panels

2.Multiple sounder outputs

3.Connection to landlord panel
 

Input Voltage AC 100-240V, 50/60Hz
Internal Power Supply DC 30V 3A
Total Output Current ≤200mA @ 220V
Chipset 32-bit Micro processor
Zone 1-8 Zone(s)
Max Number of Smoke Detector per Zone 20-25 pcs
 
Capacity High EMI Immunity
Backup Battery DC 12V/2.2AH * 2 (not include)
Dimension 325x265x100mm
Operating Temperature 0ºC ~ +50ºC
Weight(Without battery) 2700g
Material  Iron

Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
Conventional Emergency Light Monitoring Notifier System Fire Alarm Control Panel
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.
Shenzhen Puzhesi Technology Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
verified Plant Area
248 square meters
verified Number of Employees
7
verified Registered Capital
6,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-07-20
Export Year
2015-07-02
verified Main Markets
Europe, Southeast Asia/ Mideast, Domestic
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

FAQ

What is the maximum number of zones supported?
The system supports 2 to 8 zones, allowing for flexible configuration based on the installation requirements.
How many smoke detectors can each zone handle?
Each zone can accommodate a maximum of 20 to 25 smoke detectors.
What are the input voltage specifications?
The system accepts AC 100-240V, 50/60Hz input voltage for power supply.
Does the system support networking with other panels?
Yes, it supports networking mode and can connect to repeater panels, multiple sounder outputs, and landlord panels.
What is the lead time for orders?
Peak season lead time is one month, while off-season lead time is within 15 workdays.