Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light

Product Details
Customization: Available
Type: Smoke Alarm
Signal Transmission: Wired Alarm
Still deciding? Get samples of US$ 6.5/Piece
Request Sample
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
7
Year of Establishment
2012-07-20
  • Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
  • Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
  • Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
  • Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
  • Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
  • Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
Find Similar Products

Basic Info.

Model NO.
SG6008
Working Mode
Passive
Application
Indoor, Outdoor
Working Principle
Electro-Optical Type
Transmission Mode
Cable
Alarm Volume (within 1m)
≥80dB
Receive Frequency
Alarm System
Coclor
Red
Power
DC6V to 27V
Volume at 24V and 3m
75dB-110dB
Wiring Method
Two-Wire Bus (Non-Polarized)
Operating Current(Min)
5mA
Transport Package
Carton
Specification
100*45.5mm
Trademark
Alarm
Origin
China
HS Code
8531100000
Production Capacity
50000/Momth

Product Description

Features
  • Ultra low power consumption with non-polarized two wire bus.
  • Professional microchip provides highest reliability.
  • Adopt super bright LED and special structure buzzer to achieve high luminance and high sound pressure.
  • Visual or audible visual mode setting freely.
  • Each detector has a unique detector ID at the back.
  • Electrically addressed, can be modified online or by a programmer.
  • Chute designed to ease installation.
Technical Specifications
Operating Voltage Range DC6V to 27V
Monitoring Current(Max) 0.2mA
Operating Current(Min) 5mA
Volume at 24V and 3m 75dB-110dB
Change cycle 2.Os-4.Os
Flash rate
Maximum loop length
Temperature Range
Humidity
1.0Hz -1.5Hz
5km (based on ZR-RVS-2*1.5mm2)
-10 °C ~+55 °C
<95% rel. (non-condensing)
Sensor Base J-SCM08
Protection Category IP30
Dimensions( XH) 100.0x45.5mm (including base)
Wiring method two-wire bus (non-polarized)

Installation
Surface mounted, in the normal space, height 2.2m above the ground is appropriate.
  • Fix the base  (determine the installation direction according to the mark T") on the embedded junction box or the mounting location with the M4 screw.
  • Adopt ZR-RVS-2*1.5mm2 twisted pair to respectively run through the entrance holes in the base and polarity-indiscriminately connect to the S+ and S- terminals.
  • Set address (1 to 200) on the detector by programmer.
  • Install the VAD on the base.
Wiring
"S+" and "S." are the bus terminals connected to the Fire alarm control Panel(F.A.C.P.).Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
Addressable Fire Alarm System DC 24V Alarm Strobe Siren Loud Sounder with Flash Light
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier