Conventional Fire Alarm Control Panel and Monitoring System with Great Prices
Contact Supplier
Product Highlights
- Multi-Zone Capacity: Supports 4, 8, or 16 detection zones with conventional input devices.
- Comprehensive Relays: Includes 3 Form-A relays for alarm, trouble, and supervisory functions.
- Network Connectivity: Features EIA-485 port for remote annunciators and networked monitoring.
- Wide Voltage Input: Operates on AC 90-270V, 50Hz, ensuring stable power supply.
- Battery Backup: Supports up to 18 AH standby batteries for continuous operation.
- CE Certified: Product holds CE certification for safety and quality assurance.
- Flexible Configuration: Field programmable via keypad with auto/manual mode and walk test.
Product Attributes
- Customization
- Available
- Type
- Fire Alarm Host
- Function
- Networked
- Model NO.
- CK1004
- Usage
- Fire, Smoke
- Certification
- CE
- Alarm Volume (within 1m)
- ≥100dB
- Networking Mode
- Alarm
- Receive Frequency
- 485/232
- Wiring Mode
- Sub-Line System
- Weight
- 7kg
- Color
- Red
- Number of Zones
- 4
- Primary AC
- 90-270VDC
- Standby Battery
- 2*12V
- Transport Package
- Carton
- Specification
- 37*440*100mm
- Trademark
- panel
- Origin
- China
- HS Code
- 8531100000
- Production Capacity
- 500000/Month
Product Images of Conventional Fire Alarm Control Panel and Monitoring System with Great Prices
Find Similar Products
Product Description
The CK1000 is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad. It also supervises all wiring, AC voltage and battery level.
This series of panels are basically the same in application and operation, their differences are shown in Table 1-1. CK1000 will be described as the example in the following sections.
Table 1-1
| FACP | Number of Detection Zones | Number of Sounder Outputs | Output Delay Settings |
| CK1004 | 4 | 1 | N/A |
| CK1008 | 8 | 2 | N/A |
| CK1016 | 16 | 4 | N/A |
1.1 Product Features
- 4,8,16 Class B Initiating Device Circuits (IDCs)
- Four Class B Notification Appliance Circuits (NACs)
- One Form-A Alarm Relay
- One Form-A Trouble Relay
- One Form-A Supervisory Relay
- 3.0 amps of system power
- Max 20 conventional detectors in one zone.
- Auto/Manual mode setting enable walk test.
- Each Zone can be disabled,
- Sound output can be disabled.
- Manual active sound output enabled.
- Able to report short and broken circuit of detection zones.
- Designed with standby batteries and space provision for two sealed lead-acid batteries.
- Testing and disable functions
1.2 Specifications
AC Power
AC90-270 VAC, 50 Hz, 2.3 amps
Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation
Battery (lead acid only)
Maximum Charging Circuit: Normal Flat Charge-27.6V @ 0.8 amp
Maximum Charger Capacity: 18 Amp Hour batter
Sound Output Device Circuits
General Alarm Zones 1 through 16
Operation: All zones Class B
Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum)
Alarm Current: 15 mA threshold
Short Circuit Current: 42 mA maximum
Maximum Loop Resistance: 100 ohms
End-of-Line Resistor: 4.7K, ½ watt
Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone
Standby Current: 7.26 mA
Three Relays Output
Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)
Nonresettable 24 VDC Power
Maximum ripple voltage: 10 mVRMS Operating Voltage nominal 24 volts
Total DC current available from this output is up to 500 mA
Recommended maximum Standby current is 150 mA
Input Circuits
Sixteen input circuits provide configuration. Input circuits 1 through 16 may be used as standard fire alarm control panel zones. All sixteen Initiating Device Circuits accept normally-open contact devices and two-wire smoke detectors.
Output Circuits
• 24 Volt Resettable Power Output 1000 mA
• 24 Volt Nonresettable Power Output 1000 mA
• 24 Volt Battery Charger (up to 18 AH batteries)
• EIA-485 Port (interfaces to Annunciators, and Graphic Annunciators and Remote Relay Module)
Sound (Notification Appliance )Circuits
Four Notification Appliance Circuits.
Relays
Three dry relays for system alarm, system trouble and supervisory are provided standard. Contacts are rated 2.0 amps @ 30 VDC (resistive) and 2.0 amps @ 30 VAC (resistive).
EIA-485 Port
EIA-485 compatible port supports up to 10 different device addresses which can consist of Remote Annunciators, Relay Modules, Annunciators or Graphic Annunciators or any combination of the four modules.
Battery Charger
Battery Charger will charge up to 18 AH batteries. The CK1000 cabinet holds a maximum of 7 AH batteries. The external box is required to hold 18 AH batteries. The charger is rated for 500 mA maximum current.

About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR2221392". Items marked "" are certified.
Company Profile
Shenzhen Puzhesi is state high-tech enterprise and owns itself enterprise technique center. Meanwhile, we have been officially awarded as Chinese Top Enterprise for Fire Alarm Product and Chinese Top Brand for Safety&Security Product.
We makes unremitting efforts to create a safe, environmentally friendly, intelligent and comfortable living environment with its technologies and experience accumulated during its long-term engagement in the multiple professional fields of the low voltage of buildings.
We manufactures thousands of uniquely made Intelligent fire alarm control panel, smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, Puzhesi works harder to tailor our solutions to meet your needs.
Adhering to the quality policy of "Train excellent employees, produce quality products, provide excellent service" and treating the continuous improvement of customer satisfaction as its goal. We sales and technical service networks cover the entire national market and its perfect after-sales service support system and professional technical team enable it to respond to the needs of customers in time in the process of international.
About Our Factory & Business Background
-
Business Type
- Trading Company
- Address
- 3005-3005a, Bao De Industrial Center, Lixin Nan Road, Fuyong Town, Baoan District, Shenzhen, Guangdong, China
-
Plant Area
- 248 square meters
-
Number of Employees
- 7
-
Registered Capital
- 6,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Fire Alarm Control Panel, Smoke Detector, Heat Detector, Conventional Beam Detector, Extinguishant Control Panel
-
R&D Engineers
- 1 people
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2012-07-20
- Export Year
- 2015-07-02
-
Main Markets
- Europe, Southeast Asia/ Mideast, Domestic
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
FAQ
- What is the maximum number of detection zones supported?
- The CK1000 series supports 4, 8, or 16 detection zones depending on the specific model (CK1004, CK1008, or CK1016).
- What types of devices can be connected to the panel?
- It accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations, and other normally-open contact devices.
- Does the system include battery backup?
- Yes, it is designed with standby batteries and space for two sealed lead-acid batteries, supporting up to 18 AH capacity.
- What communication interfaces are available?
- The panel features an EIA-485 port to interface with remote annunciators, graphic annunciators, and optional remote relay modules.
- Is the panel field programmable?
- Yes, the FACP is field programmable via the panel keypad, allowing for auto/manual mode settings and walk tests.
- What certifications does the product have?
- The product is CE certified, ensuring compliance with relevant safety and quality standards.
- What are the power supply requirements?
- The system operates on AC 90-270V, 50Hz, with a current draw of 2.3 amps.
Send your message to this supplier
People who viewed this also viewed
-
US$25.00-35.00 / Piece
-
US$155.00-170.00 / Piece
-
US$550.00-680.00 / Set
-
US$135.00-170.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-35.00 / Piece
-
US$25.00-50.00 / Piece
-
US$50.00-60.00 / Piece
-
US$130.00-170.00 / Piece
-
US$50.00-75.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Conventional Fire Alarm System
- Others Conventional Fire Alarm System
- Conventional Fire Alarm Control Panel and Monitoring System with Great Prices
Related Categories
Hot Searches
- Fire Alarm Factories
- Alarm Security Factories
- Alarm Control System Factories
- Fire Alarm System Factories
- Alarm Control Security
- Home Security Products Alarm
- Fire Alarm Panel
- Fire Security Alarm
- Fire Security Alarm System
- Fire Alarm Control Panel Bulkbuy